(a) theaters, video hall (room), auditoriums and other performances, screening venues;
(b) dance halls, nightclubs, karaoke halls and other dance entertainment venues;
(c) with the entertainment function of the food and beverage establishments;
(d) indoor amusement, amusement parks;
(v) sports and cultural venues;
(vi) other public **** entertainment venues prescribed by the municipal people's government. Article IV of the public **** entertainment fire by the public security fire safety supervision agencies at all levels to implement supervision and inspection.
Cultural Bureau, Bureau of Technical Supervision, Administration for Industry and Commerce, Construction Management Commission, Light Industry Bureau and other departments in their respective areas of responsibility to assist in fire prevention. Article 5 of the public **** entertainment fire safety work to implement the unit responsible for, industry management, the unit's legal representative or the main person in charge of fire safety is responsible for fire safety, responsible for the unit's fire safety work.
Public **** place of entertainment contracted or leased, fire safety work by its operator is responsible for. Chapter II of the building, interior decoration fire Article VI of the new construction, alteration, expansion of the public **** entertainment venues and their interior decoration works, the design unit and the designers must implement the relevant national fire safety technical specifications, fire safety design of the project is responsible for. Construction units must be in accordance with the provisions of the fire safety design of the project submitted to the public security fire safety supervision agencies for review. Construction unit must be in accordance with the approved fire design drawings construction, unauthorized changes, and to ensure the quality of the project. After completion of the project, its fire safety facilities must be accepted by the public security fire safety supervision agencies. Article VII of the public security fire safety supervision agencies to obtain a valid engineering design certificate for the end of the unit submitted by the design and beyond the scope of the design level of the design will not be approved, and notify the relevant units will not be constructed.
Public security fire safety supervision agencies for the end of the decorative construction qualification certificate, beyond the scope of the construction level or did not obtain a construction license for the project, not acceptance. Article VIII of the public **** entertainment building fire resistance level should be one or two.
Public **** entertainment venues should be set up in the building on the ground floor to the fourth floor near the safety exit, five or more public **** entertainment venues should be set up refuge room, refuge belt or evacuation platform. Article 9 In the underground building set up public **** entertainment places, can only be set up in the ground floor, its fire unit area shall not exceed four hundred square meters, the safety exit to the ground shall not be less than two, and should be set up mechanical smoke, smoke exhaust facilities, the use of liquefied petroleum gas is strictly prohibited. Article 10 public *** entertainment shall not be set up in the historical conservation value of the ancient buildings, museums, libraries, residential buildings and important warehouses or warehouses stacking dangerous goods. Article XI of the public **** entertainment venues with a floor area of sixty square meters, should be set up two security exits, every additional four hundred square meters, should be set up an additional security exit.
The width and distance of the evacuation channel of the public **** entertainment venues, the staircase must comply with the "building design fire code" or "high-rise civil building design fire code".
The evacuation door must be opened in the direction of evacuation, and must be opened flat, the doorway shall not be set up curtains, screens and other obstructions affecting the evacuation, stairs and evacuation passageway steps, shall not be used spiral staircase and fan tread, the safety exit shall not be set up at the threshold, steps. Article XII of the public **** entertainment venues, safety exits, evacuation routes and stairs should be set up to meet the standard fire emergency lighting and safety evacuation signs. Fire emergency lighting illumination is not less than zero point five lux, continuous power supply time of not less than thirty minutes. Article XIII of the design and installation of electrical equipment in public **** entertainment venues should be in line with the relevant norms currently in force in the country, the electrical equipment used must comply with the relevant national or industry standards, and meet the following requirements:
(a) mezzanine or ceiling wiring must be used in the copper-core wires, wire joints should be welded and protected by wearing a metal pipe or flame-retardant plastic pipe. Line design load should be greater than one-third of the actual load;
(ii) the installation of fuses and switches should be in accordance with electrical codes. Must be installed to prevent leakage, overload, short-circuit electrical protection devices;
(c) electrical appliances and lamps and lanterns of high temperature parts should be set away from combustible materials, such as close to combustible materials, fire protection measures should be taken such as heat insulation and heat dissipation. Mobile lamps and lanterns must be rubber-sheathed cable wires;
(d) audio-visual equipment must be dedicated electrical protection devices;
(e) air-conditioning equipment must be set up for special power supply lines and protection devices;
(f) each single-phase circuit in the lighting system, shall not exceed 16 amperes. Article XIV of the public **** entertainment venues must be set up automatic fire alarm devices. Public **** entertainment venues with a floor area of more than four hundred square meters, should be set up to centralize the automatic fire alarm system. Set in the first floor or above ground floor area of more than one thousand square meters, should be set up fire hydrant system and automatic sprinkler system.
The first paragraph of the system should be set up in accordance with the relevant fire safety specifications.