In front of our sign circle editor has explained the 2020 hospital signage system set up standard specifications and hospital guidance signage classification, today we will briefly understand the hospital guidance signage set up location and size instructions.
Hospital guidance signs set up location and size of a simple description
First: hospital guidance signs should be set up in accordance with the different functions of the various levels of guidance signs and according to the actual hospitals, placed in the building (outside) in a conspicuous position.
Second: the setting of the hospital guide signs must be complete, clear instructions; color should be overall unity, and the overall environment of the hospital in harmony.
Third: the first level of guidance signs should be set up according to the actual situation of each hospital, should be in line with human visual habits, and can ensure that the human body from the target signage before the start of the 2-10 meters can clearly identify the effective text and content of the sign. At the same time should also meet the following conditions:
1, the hospital name signs should be set up in the main entrance to the hospital or the main building and other conspicuous location. The size of the dimensions of the hospital according to the actual situation. If you need to light up at night, you should use energy-saving facilities lighting design, its bracket should be designed by professional units, installation, and to ensure its safety.
2, the general plan should be set in the hospital's various entrances or outpatient hall in a conspicuous position. Adopt the way of standing, its external dimensions specifications range: high (1800mm-2200mm) × width (2400mm-3400mm); the way of sloping table, its external dimensions specifications are: high (1000mm-1200mm) × width (700mm -1400mm) × length (1500mm-2000mm). The floor plan must be clear, need to have a pointing northward and the current position of the floor plan set.
3, road and building-oriented signs, the name of each single building signs using ground-type or wall-type two ways. Floor type size specifications range: high (1800mm-2400mm) × width (500mm-900mm); wall type size according to the installation height and installation wall size to determine.
4, barrier-free access signs on the graphic symbols and effective text is 1200mm from the ground.
5, first aid access signs are recommended to use red (color value of C0M100Y100K0).
6, outdoor bulletin board specifications for the height of 2200mm × 3000mm wide.
Need to use the sign at night: such as emergency, first aid channel should have light-emitting signage, must use energy-saving measures of lighting design. First-class guide signs must be set up in a position to ensure that no harm will be caused to the human body due to its setup, standing signs should be set on both sides of the channel.
Fourth: the second level of guidance signs should be set up in accordance with the following:
1, the current building floor index plate, can take the standing type and wall type two forms.
Standing type: length 1700mm × width 1400mm × height 1500mm, this specification is suitable for use in small spaces. Length 3000mm x width 1400mm x height 1200mm, this specification is suitable for use in large spaces. H2000mm×W800mm, this specification is suitable for use next to the escalator or in the elevator hall.
Paste wall type: the width of vertical version is between 800mm-1300mm, the height depends on the number of floors. The height of the horizontal version is between 1200mm-1500mm, and the width depends on the number of floors.
2, open space within the signage (such as departmental guidance signs, clinic area and ward multi-directional signage, registration, pricing, charging, pharmacy and other window signs) using hanging or wall-type two forms of its width does not exceed 4 meters, the height of 280mm-450mm.
3, hanging multi-directional signage in the hallway is recommended for the width of 75% of the width of the hallway; signage height between 280mm-450mm.
4, each section of the bulletin board specifications for the height of 1200mm × width of 1200mm (width depending on the size of the wall at the installation to 600mm for the increase; the widest not more than 6000mm.
5, hanging signage according to GB/T15566-1995 to set up, that is, in the hanging signage at the bottom of the height of the ground from the ground is not less than 2 meters.
Fifth: the setup of the third-level guide signs should meet the following conditions:
1, wall-mounted horizontal diagnosis and treatment department sign, administrative office sign specifications for the high (217--290) mm × width (300--320) mm.
2, wall-mounted vertical diagnosis and treatment department sign, administrative office sign specifications for the high 317 mm × width 157 mm. 317mm×157mm wide.
3, wall-mounted horizontal type of diagnosis and treatment department sign, administrative office sign specifications: 120mm high×300mm wide.
4, ward number plate specifications for the height of 290mm×300mm wide; high 277mm×300mm wide; high 247mm×320mm wide.
5, floor plate specifications are H300mm×W300mm;H360mm×W360mm.
6, accessibility sign, safety warning signs, fire warning signs, public **** facilities sign specifications are: H230mm×W390mm (large), H250mm×W180mm (small); H200mm×W320mm (large), H170mm×W140mm (small). 140mm (small); H217mm x W300mm (large), H210mm x W162mm (small).
7, wall-mounted signs must be set up in accordance with the provisions of GB/T15566-1995, that is, the bottom edge of the signage is not less than 2 meters above the ground.
8, wall-mounted signs should be set up in line with human visual habits, that is, set the height of the bottom edge of the signage between 1.7 meters - 1.9 meters above the ground.
Related links:
1, 2020 hospital signage system set up standard specification - sign circle
2, how to categorize the hospital guidance signage? What is included?