Model: RY-IIB +
Status: Normal
Brand:
Origin: Jiangsu
Quote:
Views:
Main Parameters
Flow rate range: (0.25~15) L/min. min; Temperature range: (15~35)℃;
Product features
RY-IIB+ anesthesia workstation is a new type of anesthesia workstation adopting modern microcomputer control technology, which is suitable for modern anesthesia surgery. Novel appearance, convenient connection, excellent performance, favorable price, constitute the best performance-price ratio, so that the user gets the super value enjoyment.RY-IIB + anesthesia workstation has a strong practicality, after good experiments and tests and confirmed in the clinic, by the customer's unanimous praise.
Product Parameters
Anesthesia Machine
1, working mode: fully tight, semi-tight (0.5~7.5) kPa and semi-open;
2, gas supply: can be supplied by the central pipeline or cylinder, with a spare gas input port, rated working pressure of 0.4 MPa, allowable fluctuation range (0.27~0.55) MPa;
3, flow meter: O2: (0.1~10) L/min; N2O: (0.1~10) L/min;
4, rapid oxygen supply flow: (35~75) L/min;
5, high-precision evaporator: equipped with KT-III type of AF ether and isoflurane evaporator
Concentration range: 0-5Vol%;
Flow rate range: (0.25-15)L/min;
Temperature range: (15-35)℃;
Automatic compensation of flow rate, temperature and pressure.
Anesthesia Ventilator
1, inspiratory flow: (6~66) L/min;
2, tidal volume adjustable range: (50~1500) mL;
3, frequency: (6~99) times/min;
4, inhalation and exhalation ratio: 3:1~1:9 (inspiration time 0.3s~6.0s);
< p>5, the upper pressure limit alarm: (1.0 ~ 6.0) kPa (not lower than the lower limit);6, the lower pressure limit alarm: (0.4 ~ 4.0) kPa (delayed 4s ~ 15s);
7, the maximum safe pressure: pressure-limiting valve exhaust pressure (5.1 ~ 6.0) kPa;
8, the low ventilation alarm: when the exhaled tidal volume is lower than the minimum setting value, an alarm should be issued within 90 seconds;
9, air box tidal volume range: adult: (300 ~ 1500) mL; pediatric: (50 ~ 300) mL;
10, power failure alarm: power interruption when the sound of the alarm, the alarm lasts for not less than 120s;
11, gas source interruption alarm: gas source interruption triggers pressure Lower limit alarm;
12, the muffling time of the alarm: not more than 120s.
Product Name: GSM-Ⅲ(C) anesthesia machine
Model: GSM-Ⅲ(C)
Status: Normal
Brand:
Origin:
Quote:
Views: 317
Product parameters
▲Anesthesia host part:
●1.Mode: tightly closed, semi-tightly closed, half-open
●2.Supply gas source: O2, N2O pressure 0.3-0.5MPa
●3.Flow meter: O2, N2O two-pipe flowmeter 0-10L with linkage to ensure that the oxygen concentration of not less than 25%
●3.
●4. Rapid oxygen supply: 35L/min~75L/min
●5. Electrically controlled pneumatic fixed volume anesthesia ventilator
●6. Low air supply alarm: when O2 air supply is too low, there is an acoustic alarm for more than 7 seconds
●7. High pressure limitation: when the airway pressure exceeds the upper limit setting, the ventilator will automatically limit the pressure to ensure that it cannot continue to rise and ensure safety
●7. High pressure limitation: When airway pressure exceeds the upper limit setting, the ventilator automatically restricts the pressure to ensure that the pressure cannot continue to rise and ensure safety
. The ventilator automatically restricts the airway pressure when it exceeds the upper limit setting, which ensures the safety
●8. Adopting double-ended differential pressure flow sensor, the ventilator can monitor tidal volume, minute ventilation, respiratory rate, airway pressure, pressure waveform, flow rate waveform (in both directions), upper and lower pressure limits, asphyxiation, and oxygen concentration in real time under the two modes of machine control and manual control
●9. >▲Anesthetic evaporator part:
●High precision imported from UK (Penlon canister), double canister (AF ether, Isoflurane)
●Evaporator with flow, pressure, temperature automatic compensation function
●Concentration adjusting range:0.2-5%VOL
●Evaporator with self-locking, interlocking function
▲Anesthesia ventilator part:
●1.Applicable: adults, children
●2.Drive: pneumatic electric control
●3.Display: using 10.4 color TFT large screen display
●4.Mode: manual, automatic
●5.Tidal volume: 100~1500ml
●6.Frequency: 6~60bpm
●7. Respiratory ratio: 3:1~1:4 adjustable
●8. Upper pressure limit: 2~6Kpa
●9. Lower pressure limit: 0.6~2Kpa
●10. Monitoring parameters: tidal volume, respiratory frequency, respiratory ratio, peak airway pressure
Products
▲Presentation Configurations:
● Pediatric air box: 50-300ml
●Pediatric circuit
▲Options:
●Optional end-expiratory CO2 monitoring
●Optional external printer to record the alarm events
Product Name: Anesthesia Machine PN-2000M
Model: PN-2000M
Status: Normal
Brand:
Origin:
Quote:
Views:322
Product Parameters
Technical Parameters of Anesthesia Machine
Flow Rate Adjustment Range:
N2O:0.1L/min~12L/min,
O2:0.1L/min O2:0.1L/min~12L/min
Rapid oxygen flow: 35L/min~75L/min
Oxygen supply low-pressure alarm, N2O automatic cut-off:
Oxygen supply pressure is lower than 0.25Mpa, there is an audible alarm, the duration of which is not less than 7 seconds,
When the oxygen supply pressure is lower than 0.1Mpa, the flow of N2O will be cut off automatically.
An isoflurane vaporizer (optional imported or domestic):
Concentration range:0.25voL%~5voL%
Flow rate range:0.25L/min~15L/min
Temperature range:15℃~35℃Flow rate, temperature and pressure are automatically compensated.
Anesthesia Ventilator
Tidal volume:200mL~1200mL
Respiratory rate:10BPM~30BPM
Respiratory ratio:1:1~1:3
Pressure upper limit (restriction)
:1KPa~6KPaPressure lower limit:0~4KPa
Air box. 100mL~1500mL
Product Introduction
Product Description:
PN-2000M Anesthesia Machine
Equipped with high-precision Anflurane and Isoflurane evaporator, high-precision N2O and O2 flowmeter, Emergency Oxygen Supply Device and Oxygen Supply Low-Pressure Alarm, and N2O Automatic Cutoff. The patient circuit system meets ISO standards with hand-controlled breathing and mechanical ventilation, making anesthesia safer and more convenient.
PN-2000MII Anesthesia Ventilator
Microcomputer-controlled pneumatic electrically controlled ventilator with intuitive operation and complete functions.
Product Name: Multi-function Anesthesia Ventilator PN-200OMD
Model: PN-200OMD
Status: Normal
Brand:
Origin:
Quote:
Views: 349
Product Parameters
Anesthesia Ventilator Technical parameters
Flow rate adjustment range:
N2O:0.1L/min~12L/min,
O2:0.1L/min~12L/min
Rapid oxygen flow rate: 35L/min~75L/min
Oxygen supply low-pressure alarm, N2O automatic truncation:
When the oxygen pressure is lower than 0.25Mpa, it can be cut off automatically. 0.25Mpa, there is an audible alarm, the duration is not less than 7 seconds,
When the oxygen supply pressure is lower than 0.1Mpa, the N2O flow is automatically cut off.
An isoflurane vaporizer (optional imported or domestic):
Concentration range:0.25voL%~5voL%
Flow rate range:0.25L/min~15L/min
Temperature range:15℃~35℃Flow rate, temperature and pressure are automatically compensated.
Anesthesia Ventilator:
Tidal volume:200mL~1200mL
Respiratory rate:10BPM~30BPM
Breathing ratio:1:1~1:3
Pressure upper limit (restriction)
Pressure limit:1KPa~6KPa
Pressure lower limit:0~4KPa
Airbox. 100mL~1200mL
Product Introduction
Product Description:
PN-2000MD Multifunctional Anesthesia Machine
Consists of anesthesia machine and anesthesia respirator. Anesthesia machine microcomputer control pneumatic electric control ventilator, operation is intuitive, full-featured. The anesthesia ventilator is equipped with high-precision amfluoroethylene and isofluoroethylene vaporizers, high-precision N2O and O2 flow meter, emergency oxygen supply device and oxygen supply low pressure alarm, N2O automatic cut-off. The patient circuit system meets ISO standards with hand-controlled breathing and mechanical ventilation, making anesthesia safer and more convenient.
Product Name: RY-IIA Anesthesia Machine
Model: RY-IIA
Status: Normal
Brand:
Origin: Jiangsu
Quote:
Views: 153
Main Parameters
Concentration Range: 0 to 5 vol%; Temperature Range: (15~35)℃; Flow rate range: (0.25~15)L/min;
Product Parameters
Gas Supply Pressure: Rated Working Pressure 0.4MPa, Working Pressure Range (0.27~0.55)MPa, Cylinders or Center Pipeline Gas Supply;
Flow Rate: O2: (0.1~10)L/min, N2O: (0.1~10)L/min, N2O: (0.1~10)L/min. 0.1~10)L/min;
Flow control valve: oxygen and laughing gas linkage mechanism to ensure that the oxygen concentration is not less than 25%, the oxygen flow control valve is not open laughing gas can not enter the anesthesia respiratory system;
Rapid oxygen flow: (35~75)L/min;
Respiratory circuit: working mode: fully closed, semi-tightly, semi-open (1~4) kPa; expiratory, open (1~4) kPa; expiratory, open (1~4) kPa, open (1~4) kPa, open (1~4) kPa. )kPa; expiratory and inspiratory impedance: not more than 0.6kPa;
Vaporizer: Configuration KT-II type of amflurane or isoflurane vaporizer
Concentration range: 0-5vol%;
Temperature range: (15-35)℃;
Flow rate: (0.25-15)L/min;
Rapid oxygen supply flow: (35-75)L/min;
Automatic compensation of flow rate, temperature and pressure.
Product Introduction
RY-IIA anesthesia machine, which can meet the basic clinical requirements for use, has a reasonable layout and simple structure and is suitable for use in hospitals of all levels. The circuit system conforming to ISO standard, with multiple working modes of fully tightly closed, semi-tightly closed and semi-open, is applicable to children and adults above 4 years old, with no limitation of cases, and pediatric anesthesia circuits can be purchased from the manufacturer when used for children below 4 years old.
Product Name: American VME Animal Anesthesia Machine
Model: VME
Status: Normal
Brand:
Origin: USA
Quote: Negotiable
Views: 193
Product Features
1, professional closed respiratory circuit:
1. p>
2, accurate oxygen flow meter, stable output, with fast oxygen filling function. With fast oxygen filling function; optionally equipped with dual flow meters
3, with APL automatic pressure relief safety function: to avoid excessive air pressure pressure on the animal pressure injury
4, with pressure detection function
5, with a patented air inlet valve: allows the animal to breathe the atmosphere even after the oxygen supply stops. Ensure the safety of the animal in case of accident
6, with carbon dioxide absorption system:
7, with expiratory and inspiratory valves: the respiratory state of anesthetized animals can be clearly observed: inhalation or exhalation
8, the structure of the design of a compact and flexible mobile, with portable handles, easy to use;
Product Name: TIAC-I Intravenous Anesthesia Controller (target control pump)
Model: TIAC-I
Status: Normal
Brand:
Origin: Guangdong
Quote:
Views: 199
Main Parameters
Precise Control: Volume Error ± 2%
Product Features
1. 1、After 18 years of clinical research, it is the only intravenous anesthesia control device that can administer drugs according to the pharmacogenetic and pharmacodynamic parameters of Chinese people, with stable anesthesia control;
2、Choose 7 intravenous anesthetics commonly used in the clinic, and all the data come from the clinic;
3、Choose the first-class imported injection system, with stable performance;
4、Large liquid crystal screen, Chinese menu interface, easy to operate;
4、Large LCD screen, Chinese menu interface, easy to operate. Simple operation;
5. There are two types of drug delivery modes: target-controlled mode and constant-rate mode, and plasma or effect chamber concentration mode can be selected for target-controlled mode;
6. It has independent intellectual property rights, and has been awarded 3 national patents, and has published more than 90 academic papers and two treatises;
Product Parameters
Precise control: capacity error ± 2%;
The battery can work continuously for more than 6h under fully charged state.Product Introduction
The first one in China to adopt the national intravenous anesthesia parameters, choose the world's first-class hardware, and develop the "Intelligent Intravenous Anesthesia Controller" with independent intellectual property rights.
Personally, according to my own experience and experience, I feel that Beijing Yian's machine is relatively good
Not to belittle the domestic manufacturers domestic anesthesia machines, whether it is the stability or ease of use safety than the imported machine is too much If you are selecting your own Remember that there is one thing that the key components as long as they are imported this anesthesia machine's performance is most likely better Purely domestic is not recommended
Still recommend the German Dr?ger and the United States of America, and the United States of America. Germany's Dr?ger and America's Omidyar are safe to use, so don't put yourself in fear.