Installation and setting of hospital medical software (1) dynamic electrocardiogram
2
Open the installation file of dynamic electrocardiogram software, which should have the following files.
Installation and setting of hospital medical software (1) dynamic electrocardiogram
three
Copy all the documents in the installation file to the computer hard disk.
Change the file attribute in the installation file from read-only to archive.
Installation and setting of hospital medical software (1) dynamic electrocardiogram
four
The desktop shortcut to send "BP_PROU.exe" in the file is icon properties-Send to-Desktop Shortcut.
Installation and setting of hospital medical software (1) dynamic electrocardiogram
five
On the desktop icon, install the following icon operation to change it to the correct icon.
Installation and setting of hospital medical software (1) dynamic electrocardiogram
Installation and setting of hospital medical software (1) dynamic electrocardiogram
Installation and setting of hospital medical software (1) dynamic electrocardiogram
six
Click the changed desktop icon to use it.
But you need to check whether the battery of the recording box is sufficient. If "B" is displayed, replace the battery in time, install the battery in the correct polarity direction, turn on the switch next to the battery and cover the back cover. Note: Old and new batteries must not be mixed! It is recommended to replace the battery after measuring two or three patients.
Connect the computer to the recording box.
Carefully remove the rubber cover that protects the data port, insert the round head of the data cable into the data port of the data box, and when you hear the beep, the recording box will display "-",indicating that the recording box has been connected to the computer.
Installation and setting of hospital medical software (1) dynamic electrocardiogram
seven
Open the dynamic blood pressure analysis software on the desktop, in the software menu, open the "record box", "Settings",
Installation and setting of hospital medical software (1) dynamic electrocardiogram
eight
Set blood pressure measurement interval
1, blood pressure measurement interval (according to hospital requirements) is every 30 minutes from 07: 00 to 22: 00.
22:00-07:00 1 hour.
2. Click OK, and the software will ask whether to delete the record box data and set it according to the current time. Click Yes.
(Please make sure that the time setting on the computer using the software is correct. )
3. After setting the recording box, immediately disconnect the recording box from the data cable and cover it with a rubber cover. The record box is ready, showing the current time.
4. All installation settings have been completed and can be used immediately.