Extended data:
Sterile goods management:
1. Strengthen the monitoring of washing quality of syringes, needles and other articles, and conduct routine glucose tolerance measurement, heat source measurement and bacterial monitoring once a month. Transparency and PH are measured twice a week.
2, all kinds of disinfection logo is clear and complete, there must be a name, effective date, responsible person, reviewer. Unclear identification and incomplete records shall not be issued. Each package should be affixed with adhesive tape and 132℃ pressure steam sterilization indicator tube to determine the sterilization effect. If it does not meet the requirements, it should be sterilized again.
3. Strengthen the management of disinfection work. The sterilizer should strictly implement the operation procedures of high-pressure sterilization to ensure the disinfection effect. Check and record the sterilization temperature, pressure, time and indicator display results in time, and keep them for 7 days according to the regulations. Every morning, each pre-vacuum autoclave should be tested once before sterilization. The supply room shall be supervised and inspected by the quality supervisor at any time.
4. In order to ensure the effect of autoclaving, thermophilic acidophilic lipase is used as indicator bacteria once every quarter to determine the effect of thermal sterilization.
5. Sterilized sterile articles should be kept clean, dry and pollution-free during transportation. Vehicles in the disinfection room (divided into sterile goods vehicles and cleaning goods vehicles) should be wiped with disinfectant every day and marked.
Sterile room management:
1, the sterile room is ventilated and dry, and should be exhausted.
2, indoor, cabinet clean, without sundry, no dust, cleaning tools (mop, rag, etc. ) special, marked, should use disinfectant wet wipe twice a month.
3. Full-time staff are relatively fixed. Before entering the room, they should wash their hands, wear masks and change shoes, and strictly implement aseptic operation procedures. Other personnel are not allowed to enter.
4. When receiving sterile items, check whether the identification is complete, whether the cloth is clean and dry, whether the hole of the syringe box is closed, and monitor whether each package of 3M adhesive tape achieves the sterilization effect. Articles should be placed in order. Check once a month, and there shall be no expired items. The validity period is usually 7 days, and the mildew season is 5 days. Expired or suspected pollution should be disinfected again.
5, sterile room disinfection qualified, air culture bacteria number is less than 4 fu/(φ 90 mm plate. 5 minutes).
6. Wipe the ultraviolet lamp tube with 95% alcohol in the sterile room and each packaging room every day, and record the irradiation time. Use the ultraviolet intensity card to test the intensity every 60 days (2 months). Below 70μw/cm2, report to hospital infection department. If it is lower than 70μw/cm2, replace the lamp tube.
Disposable articles:
1. The supply room shall uniformly receive a certain amount of disposable medical supplies from the equipment warehouse. At the same time of purchase, carefully check whether the three certificates of the product are complete, and at the same time check the batch number, production date, manufacturer, disinfection date, packaging disinfection label and other indicators, and use them only after they are qualified.
2, for each batch of disposable infusion supplies should be sampled to check the heat source reaction, bacterial culture, after the indicators are qualified, can be distributed to clinical departments. For patients to use.
3. Ask the opinions of all departments at any time. If the infusion set leaks or leaks, please contact the Equipment Department or return it in time.
4, all kinds of infusion supplies by the supply room unified in the form of one-on-one exchange to the clinical departments, timely recycling used disposable supplies.
5. Soak the recovered disposable goods evenly in the disinfectant of Shikang (1: 100), take it out and drain it after half an hour, and fix the deformation.
6, a month by the health department (bureau) designated by the recycling unit unified recycling disposable supplies.