What are the requirements of medical airtight door

Summary: medical airtight door is mainly used in hospitals, computer rooms and mining, hospital CT room, X-ray room, operating room, detection room, etc., mainly by setting up a lead plate inside the door to block radiation, lead as the main functional material, stainless steel as the support material, made of a special-purpose medical airtight door. Medical airtight door thickness, door thickness of not less than 45mm, steel plate thickness of not less than 1.0mm, the specific value can be customized, in addition to the thickness, what are the requirements of medical airtight door? Together to the text to see it! First, the thickness of the medical airtight door how much better

Medical airtight door is often used in medical places, because the type of medical airtight door there are a variety of medical airtight door manufacturers have to be strict control of the quality of the product, so that we can provide our customers with better products as well as services. So here's a look at it. Manufacturers in the production of medical airtight door thickness how much better:

1, the door thickness of not less than 45mm, steel plate thickness of not less than 1.0mm, no exposed screw holes as well as welding points, welds, to ensure that the door overall strength.

2, the door frame steel plate thickness of not less than 1.5mm, using cold-rolled hot-dip galvanized steel, in accordance with the actual thickness of the wall at the installation site to provide all-inclusive wall door frames, horizontal and vertical frames 45 degrees diagonal.

Two, what are the requirements of medical airtight door

In addition to the thickness, medical airtight door has the following requirements:

1, the overall requirements: medical airtight door manufacturers should be designed to the appearance of the surface is flat and smooth, no depression or damage, paint evenly distributed, there should be no heap of paint, small bubbles and other issues, door deformation ≤ 3mm, the door and the door frame joints need to install Rubber sealing strip on three sides, rubber sealing strip using non-glue inlay technology.

2, the appearance of the treatment: the use of paint spraying equipment to complete the electrostatic spraying, need to have wear-resistant dust, antibacterial, spray surface flatness.

3, filler materials: the use of high strength paper honeycomb or aluminum honeycomb, and the steel plate will not have gaps to ensure the strength of the door, knocking does not appear hollow sound.

4, door frame deviation: the installation of the door frame width error in about 1mm: the verticality of the two vertical frames can not be greater than 2mm, the diagonal difference of the door frame is not greater than 3mm.

5, hardware requirements: hinges, hardware, locks and other accessories such as accessories using 304 stainless steel shall be presented in accordance with the standard relevant recognized inspection reports. Hardware fittings, accessories, reinforcements should meet the functional requirements, the location of the correct, complete, solid, with sufficient strength, open and close easily, no noise.

6, equipped with glass windows: windows with tempered glass windows, window bars for aluminum alloy bars, the surface without screws and welds.