How to select the chlorine dioxide generator? What are the basis?

How to calculate the selection of different water quality chlorine dioxide generator? Ltd. Li Guoping for you to answer

Run clean environmental protection water treatment equipment chlorine dioxide generator from the big aspects of chemical method, electrolysis, positive pressure, negative pressure, high purity, composite and so on; we mainly from the perspective of chlorine to give you a friend to do an introduction:

1, the different water quality should be processed to achieve what kind of standards?

Drinking water: GB5749-85

Project standard

Total bacteria ≤ 100 / ml

Total coliforms ≤ 3 / ml

Free residual chlorine in contact with the water for 30 minutes is not less than 0.3mg/L

Trichlorine 60ug / L

Swimming pool water: Hygienic Standard for Swimming Places"

●Free Residual Chlorine: 0.4?0.6mg/L

●Chemical Residual Chlorine: >1.0mg/L

●Total Coliform Bacteria: <18/l

●Total Bacterial Counts: <1000/ml

Hospital Wastewater: Hospital Wastewater Discharge Standards (GBJ48-83)

Hospital wastewater: "Hospital Wastewater Discharge Standards (GBJ48-83)

Hospital wastewater: "Hospital Wastewater Discharge Standards (GBJ48-83)"

●Three consecutive times, 500ml of each test, shall not be detected enteric pathogenic bacteria and bacilli;

●Total coliforms shall not be greater than 500 / L

Central water: "miscellaneous water quality standards for domestic water" (CJ25.1-89)

●Free residual chlorine: the end of the pipe network is not less than 0.2 mg /L

●Total coliforms: <3 /L

2, the amount of effective chlorine added to various types of water bodies?

di drinking water 0.5g/m3 - 1.2g/m3

di surface water drinking 2g/m3 - 4g/m3

secondary water supply 0.1g/m3 -0.5g/m3

Swimming pool water 2g/m3-5g/m3

Hospital sewage 30g/m3-50g/m3< /p>

Central water 5g/m3-8g/m3

Industrial circulating water 3g/m3-5g/m3

Other tests to determine

3, the actual application of examples:

A hospital design beds 175, now to choose a chlorine dioxide generator for the hospital's sewage treatment, to meet the requirements of discharge standards, chlorine dioxide generator selection is as follows:

Hospital beds:

Average hourly flow of sewage:

Q1=175 × 0.5 ÷ 24=3.6m3/h

Variable parameters:

k=2.5

Maximum hourly flow of sewage:

The maximum hourly flow of sewage:

The maximum hourly flow of sewage:

Maximum flow rate of sewage: Q2=3.6×2.5=9m3/h

Contact time: more than half an hour

Generally, the hospital sewage treatment required for the dosage of pharmaceuticals: 30-50g/m3

Maximum amount of pharmaceuticals per hour: Q3=9m3/h×50=450g/h

So the hospital selected HB -500 type chlorine dioxide generator that can fully meet the requirements of sewage disinfection treatment