? (A) the ease of use: Shanghai Jimmy high-end DR machine based on the global unity of the concept of multi-system control and the establishment of an integrated operating system. This operating system in a work surface covers all the work of radiography, including patient data registration, pre-exposure preparation, exposure program selection, image measurement and post-processing, image printing and archiving, report production and so on. Low-end DR machine home also used X-ray system parameters, exposure program selection and patient data registration, image measurement and image post-processing, image printing and archiving, report production and other independent of the separate operating system.
? (B) Functional intelligence: The most prominent feature of Shanghai Jimmy's intelligent pet DR machine is the standard automatic exposure control function. According to the thickness of the illuminated body, physiological and pathological characteristics, given the appropriate KV, the automatic exposure control function can accurately and automatically control the X-ray dose to obtain the appropriate amount of light sensitivity, when the sensing device receives enough X-ray dose, the device will automatically cut off the exposure, to ensure excellent image results. The application of the automatic exposure control technology allows the vet to be able to skillfully use the entire DR machine relatively quickly without the need for extensive clinical experience. This effectively reduces the need for repeated X-ray filming in some pet hospitals due to improper operation or poor skills of doctors. This greatly reduces the dose of X-rays received by healthcare professionals and patients, while the output of high-quality images also guarantees clinical diagnostic results!
? (C) the rationality of the configuration: radiological imaging equipment, the advantages and disadvantages of comprehensive performance, image quality is the most simple and effective sign. The quality of the image depends on the quality of the image chain, it is worth paying special attention to the comprehensive performance of a piece of equipment is not dependent on the equipment's most excellent that component and parameters, but by the worst that component and the lowest of that parameter to decide, just like a barrel, how much water can be loaded, is not dependent on the longest piece of board, but by the shortest piece of board to decide, so, when buying and selling the whole DR machine, to pay special attention to the worst part of the system, to make sure it is the most effective. Therefore, when purchasing a DR machine, special attention should be paid to whether the worst components and the lowest parameters in the system can meet the demand and whether the configuration of each component is reasonable. To especially prevent the phenomenon of big horse-drawn carts or small horse-drawn carts.
? (D) quality service: purchase a good DR, in addition to the DR's own "hardware", but also pay attention to whether the manufacturers have quality after-sales service. A DR machine life is generally 6-8 years, the number of bulb exposure in 8-10 million times, which is a long journey, during the use of only manufacturers can really give the machine on a long-term "safety lock", encountered unexpected situations can quickly respond to ensure that the machine according to the normal track, in order to let the vet really Reassurance, to avoid the machine sold 2, 3 years after the situation of no one to manage. Shanghai Jimmy * engineers team is 7 * 24 hours for everyone!
? Here to talk to you mainly about the intelligent pet DR machine automatic exposure control system:
? Automatic exposure control system is the use of X-ray sensors to detect the amount of radiation through the illuminated object to reach the plate detector, thereby controlling the exposure time of X-rays, which can be made to different parts of the different illuminated objects photographed by the X-ray image with the same amount of light sensitivity, a complete solution to the problem of inconsistent X-ray sensitivity of the conventional DR machine.
? How does the automatic exposure control system work? Please see the following automatic exposure control system workflow:
? 1. X-rays pass through the illuminated object and arrive at the automatic exposer
? 2.? The autoexposer receives the X-rays and generates an ionization signal
? 3. The ionization signal is amplified and sent to the backend
? 4.? The auto-exposer circuit comparator compares with the preset parameters
? 5. If the received X-ray dose has reached the required level
? 6.? The auto-exposer circuit comparator sends a signal to cut off the bulb tube and the high voltage generator
? 7. The X-ray exposure cuts off, stopping the shot
? Conventional DR machines usually require our vets to adjust KV, mA, mA/s by calculating formulas, whereas Shanghai Jimmy's high-end auto exposure DR machines require only one parameter to be adjusted, and the film can be taken under the precondition of correct positioning. The automatic exposure control system is used to accurately control the exposure time of X-rays, exposure dose!
Image effect sharing
Pet DR machine examination has become a routine means of examination of pet hospitals, as a pet hospital director said, "to open a hospital, you can not buy high-end ultrasound, but absolutely can not not not buy the DR machine". With the continuous popularization of DR machine products, especially in the era of rapid development of pet medical technology and service capabilities, we should use advanced equipment to serve pets, Shanghai Jimmy high-end automatic exposure DR machine, your best choice!