What kind of non-standard automation equipment is seal leakage detection equipment?

Seal leakage testing equipment is through the test seals as a medium, sealing fixture on the upper side of the water, the lower side of the container vacuum way to detect the test seals whether the leakage of the device, when the leakage occurs, the water droplets flow into the container at the bottom of the sensor, sensor detection, equipment alarm and record the results of the test process pressure - time curve can be displayed in real time, you can check the history of the record, the equipment machine is made of stainless steel and organic glass and other non-rust materials, safe to use. Plexiglass and other non-rusting materials, the use of safe, today from the main function of the equipment, equipment composition, and equipment installation of these three aspects to talk about this seal leakage testing non-standard automation equipment.

Main function

1. Vacuum function, vacuum pump to the vacuum tank vacuum, vacuum tank for the container to provide sufficient vacuum source, to ensure rapid vacuum detection.

2. Vacuum pressure control function, through the valve automatic action control to reach the set pressure value.

3. Pressure preservation and pressure relief function, set the pressure preservation time for pressure preservation, and realize pressure relief through valve action.

4. Pumping function, the equipment is equipped with a pump, people work to hold the suction pipe to pump away the waste water after the test, back to the collection bucket.

5. Waste water tank full of liquid prompt function, waste water tank is installed with a liquid level sensor, when the liquid level reaches the detection of the alarm prompts the user to clean up.

6. Data reporting and viewing function, test results saved and view history, can be copied via USB.

Equipment Composition

Sealing leakage testing equipment for the one-piece structure, the entire equipment is compact, easy to install and use, plug and play. The equipment is mainly composed of stainless steel cabinet, vacuum system, pressure control system, test tooling, air blowing, waste liquid collection, electrical control, operation touch screen and other structures.

Equipment installation precautions

1. Can only be installed in a dry, ventilated room, the room does not contain corrosive gases.

2. Installation altitude less than 1000m.

3. Ambient temperature between 22℃~25℃ (about 23℃ is the best).

4. Protect the electric control cabinet, hydraulic power cabinet, from direct sunlight.

5. Humidity: relative humidity below 55% R.H..

6. Ground level and leveling: very small unevenness is allowed (within the range of caster adjustment).

7. Occupied space size: hydraulic power cabinet external dimensions: L × W × H = 1200 × 600 × 1700mm

8. Power supply AC220V ± 10%, 50HZ.

Equipment placed in the installation position after adjusting the caster red runner, so that the roller off the ground, while adjusting the four wheels, so that the equipment level can be.