Steps to move an air conditioner outside the air conditioner to move the air conditioner

Air conditioners bring us a lot of convenience in summer and winter, and the outer boxes of air conditioners are installed outdoors. Air conditioner moving is not some simple operation, not to mention that you can not just find a repair point to move in order to save money, it will not pay off. Air conditioning is generally divided into several steps to operate, in order to better maintain our air conditioning, air conditioning to use a longer period of time, ask a professional master to move is the most appropriate! Today, I will give you the steps to move the air conditioning unit and the precautions you can understand.

Steps to move the air conditioning machine

1. Moving personnel need to be ready for all the full set of tools as well as safety equipment, to ensure that all steps to operate.

2. Recovery of refrigerant, first of all, to start cooling, outside the machine running after the collection of fluorine to close the small valve, the valve frost has melted off after closing the large valve, immediately shut down the machine. Pull off the power supply, tighten the insurance cap, so that the air conditioner to move the machine in the refrigerant collection to the outdoor unit.

3. dismantle the indoor unit, dismantle the indoor unit, should prevent condensate flow into the circuit board;

4. dismantle the outdoor unit, dismantle the outdoor unit should be unloaded at the same time pay attention to the balance of the vibration to avoid shaking, and finally wrapped in plastic in order to carry.

5. Air conditioning reinstallation should pay attention to the installation location and convection. Finally, with the detergent leak detection, observation of each joint there is no bubble out of the system to verify that there is no leakage, tighten the valve safety cap can be.

Precautions for air conditioner removal

1, test the air conditioner to see if all functions work properly before removal.

2, the recovery of refrigerant, remove the indoor and outdoor connection line. It is best to mark the ends of the connecting wires so that there is no possibility of connecting the wires incorrectly and causing a malfunction when installing the air conditioner.

3, outside the machine handling, installation process, can not be flipped, tilt angle is too large, do not use your hands to grab the shut-off valve to lift the machine.

4, terminals or other wiring is loose, to prevent the occurrence of fire or other hidden dangers, whether the wire is aging phenomenon, such as aging must be replaced.

5, the old air conditioner can not be stopped in 3 minutes after the restart, or easy to burn the compressor. Newer air conditioners have a circuit that prevents them from restarting within 3 minutes, and even if they restart within 3 minutes, the compressor will not work.