Gree air conditioning does not cool only blowing wind
Possible reasons are: air conditioning fluorine, looking for professional maintenance workers to come over to add fluorine can be; refrigeration tube is damaged, replace a new refrigeration tube; improper installation location, you need to avoid direct sunlight; air conditioning has not been cleaned, the air conditioning dust net will be taken down to clean clean can be; voltage is insufficient, wait for the voltage to stabilize or overhaul the circuit. If you find that your air conditioner's cooling effect is not good, you can consider whether the air conditioner lacks fluorine. The air conditioner lack of fluorine only need to find professional maintenance workers to come over to add fluorine can be. Refrigeration tube damage air conditioning does not cool may also be the refrigeration tube is damaged, the refrigeration tube is broken can look for maintenance personnel to find a refrigeration tube, if that will do it yourself to replace the words, you can do it yourself to replace a new refrigeration tube. Improper installation location of the air conditioning installation location should also pay attention to the air conditioning installation must pay attention to the pre-installation of the air conditioning should not be installed in the sun is very strong place, strong direct sunlight, as well as direct sunlight long enough, will lead to the external machine beyond the normal working environment, resulting in the air conditioning of the normal cooling effect is not good. Air conditioning is not cleaned air conditioning in use is also important to pay attention to clean up the work, if it is found that the air conditioning does not cool only blowing, you need to first open the shell of the air conditioning to see the air conditioning inside is not too dirty, if it is found that there is a lot of dust, then it is the air conditioning of the air conditioning of the dust blocked air conditioning air outlet, resulting in air conditioning does not cool, this time will be the air conditioning dust mesh down to clean it can be done. Insufficient voltage air conditioning voltage is not enough air conditioning does not cool an indirect cause, our air conditioning normal start-up voltage should be 220v, and our phase voltage 220V, line voltage in the 380V power supply system, as long as the voltage is above 200V almost all the compressor can start. Just wait for the voltage to stabilize or overhaul the circuit. The answer applies to most air conditioner models such as gree/Gree KFR-50GW.