1, fever clinic should have the function of pre-screening, triage, screening, and equipped with relevant equipment and facilities. Medical institutions that do not have a fever clinic should develop a plan and set up a relatively independent, well-ventilated fever screening area for temporary screening, isolation, and transfer. Ensure early detection, early reporting, early isolation and early treatment.
2, fever clinic site selection. Fever clinic should be set up in the medical institutions in a relatively independent area, and general outpatient (emergency) clinic is relatively isolated, and should be close to the emergency room, set up a relatively independent entrance and exit, easy to screen patients, transfer. And, the conditions of the fever clinic should be reserved outdoor space and equipment pipeline conditions, for the future rapid expansion, transfer and other basic conditions.
3, for medical institutions with fever clinics and fever screening sites. The main entrance to the hospital area and outside the emergency room hall should be set up a conspicuous fever clinic signs, clear fever clinic in the direction, location and route. The hospital area should be set up route guide signs, clear patients to the fever clinic route, as far as possible to avoid crossing other buildings.
4, in the fever clinic layout. plan layout should be divided into clean area, semi-polluted area, polluted area, and set up conspicuous signs. The three districts are not cross each other, the use of the area should meet the daily diagnosis and treatment work and life needs. Among them, the patient's activities should be limited to the contaminated area, medical staff general work activities should be limited to the clean area; semi-contaminated area is located in the transition between the clean area and the contaminated area.
The contaminated area mainly includes the patient's entrance area, triage, waiting, consultation room, isolation observation room, radiological examination room, test, disposal room, rescue room, dirt room, patient bathroom and so on.
5, for the number of consultation rooms and isolation observation room. That is, the consultation room should be no less than two; isolation observation room no less than one. In line with the principle of resource **** enjoyment, rational allocation, test room, PCR laboratory should be relatively independent of the establishment, may not be limited to the fever clinic area.