How to maintain the maintenance of medical air sterilizer

Summary: Medical air sterilizer is a medical device, in normal use, pay attention to the maintenance of the case, usually can be used for about 5-10 years, but if you do not pay attention to the maintenance and maintenance, may be shortened service life, and often out of order. Maintenance and care of medical air sterilizers should pay attention to regular cleaning, regular inspection, choose the right use of the environment, strictly in accordance with the requirements of the instruction manual, found faults in a timely manner overhaul and so on. Below to learn about the service life of medical air sterilizer and maintenance methods. A medical air sterilizer service life is how long

Buy medical air sterilizer, pay attention to its service life, a good medical air sterilizer, its service life is relatively long, and in the process of use is not prone to failure damage, then how long the medical air sterilizer can be used?

Generally speaking, the service life of the medical air sterilizer is still relatively long, in normal use, pay attention to do a good job of basic maintenance and maintenance work, a medical air sterilizer can be used for about 5-10 years, pay attention to do a good job of maintenance work, the service life will be slightly extended. Ultraviolet disinfection principle of medical air sterilizer to note that the use of cumulative time more than 5000-7000 hours, then the need for ultraviolet lamp replacement.

Two, how to maintain the maintenance of medical air sterilizer

In order to extend the service life of the medical air sterilizer, to prevent frequent damage, you need to pay attention to do a good job of maintenance of medical air sterilizer, to do:

1, to keep the medical air sterilizer clean and dry, clean the surface on a regular basis, clean the power supply should be cut off and unplugged, to avoid direct contact with water or rinse. or rinse.

2, in the use of medical air sterilizer, to avoid objects or hands close to the sterilizer ventilation inlet and outlet.

3, medical air disinfector need to check regularly, found that the work is abnormal, should immediately turn off the power switch, and pull out the power plug, timely notification of maintenance personnel to check and repair.

4, every two weeks to clean the filter, if there is dust in a timely manner with water or water with neutral detergent cleaning, is strictly prohibited to use a brush type of tool scrubbing, washing clean and placed in a cool ventilated place after drying, according to the original way to install back, and make a good record.

5, medical air sterilizer should not have any cover above, and can not be placed in the cabinet and other environments to use.

6, mobile medical air sterilizer should be careful to push lightly when moving to reduce vibration.

7, the installation and use of medical air sterilizer should be carried out in accordance with the instructions, without guidance, training, detailed reading of the instructions is strictly prohibited, the use of electricity should pay attention to safety.