1. Amend the second paragraph of Article 2 to read: “Secondary water supply facilities as mentioned in these regulations refer to pump rooms, pools (tanks), pipes, valves, and water pump units set up for secondary water supply. , disinfection equipment, pressure water containers and other facilities.” 2. Amend Article 4 to “The municipal water administrative department is the administrative department in charge of secondary water supply management in this city, and its affiliated secondary water supply management agency is specifically responsible for the city’s secondary water supply management. Supervision and management of secondary water supply. The health administrative department is the city's secondary water supply sanitation supervision administrative department, responsible for the sanitation supervision of secondary water supply.
Yanliang District, Lintong District, Chang'an District, The water administrative departments of Gaoling District, Huyi District, Lantian County, and Zhouzhi County are responsible for the supervision and management of secondary water supply within their jurisdictions.
Housing construction, resource planning, fire protection, market supervision, public security and other departments shall follow the regulations. Within their respective scope of responsibilities, they should coordinate the management and supervision of secondary water supply. "3. Add one article as the revised Article 5: "Secondary water supply should adopt safe, reliable, hygienic and environmentally friendly, energy-saving and water-saving technologies and equipment, and implement them. Intelligent management.
Secondary water supply management agencies should provide guidance on the selection of energy-saving and environmentally friendly equipment and materials for secondary water supply and publicity and training for the secondary water supply industry. "4. Article 6 shall be revised. Article 7 of the Article 7 is revised to read: “The design plan for new, reconstructed, or expanded secondary water supply facilities shall meet the basic conditions and management requirements for connection with the urban public water supply network. The design and construction of secondary water supply facilities shall be implemented Relevant standards of the country, the province, and the city." 5. Article 7 will be changed to Article 8, and be revised to read: "The design and construction of secondary water supply facilities must meet the following requirements:
( 1) The volume of the pool (box) and the diameter of the water pipe should meet the water requirements;
(2) The top and surrounding drainage of the reservoir should be smooth, and the necessary number of ventilation holes must be provided on the top of the reservoir;
(3) The wall of the pool should be strong, smooth and non-leaky, the pool (box) cover should have good sealing performance, and the ventilation holes should have devices to prevent mosquitoes and foreign objects from entering the pool;
(4) ) The secondary water supply pump room should be set up separately and should not be mixed with fire protection and other pump rooms. The pump room should have an independent electricity metering device that can be used for trade settlement. The storage pool should be built separately from the fire protection pool to facilitate cleaning and maintenance;
(5) Secondary water supply and storage facilities should be set up separately and equipped with devices to prevent water pollution;
(6) If residential and non-residential buildings are in the same building, secondary water supply facilities should be set up separately ;
(7) Within 30 meters around the secondary water supply facilities, it is prohibited to pile up toxic, harmful, and perishable substances, and it is prohibited to set up seepage toilets, seepage pits, cesspools, garbage dumps and other pollution sources;
p>
(8) Facilities such as water storage, water distribution, water delivery, and overflow shall not be directly connected to drainage facilities;
(9) Building materials, pipes, and valves shall comply with hygiene and quality requirements;
(10) Security technology prevention systems such as monitoring systems and intrusion alarm systems should be constructed, physical defense facilities such as anti-theft doors and windows, lockable plate covers, and protective nets should be installed to prevent malicious damage, and closed management should be promoted;
(11) The water pump unit operates normally;
(12) Other requirements stipulated by laws and regulations. 6. Replace Article 9 as the revised Article 10, and amend the second paragraph to read: “After the secondary water supply facilities are completed, the construction unit shall organize acceptance inspection, and shall notify the water administrative department and health administration department during the acceptance inspection. departments participate. If it has not been inspected or failed to pass the acceptance inspection, it shall not be put into use. "7. Add one article as the revised Article 11: "Secondary water supply facilities shall be managed and maintained by their property owners or the units entrusted by them. 8. Article 12 will be regarded as the revised Article 14 and be revised to read: "The cleaning of secondary water supply facilities shall be managed uniformly by the municipal water administrative department, a cleaning notice system shall be implemented, and the cleaning of secondary water supply facilities shall be independently selected by the secondary water supply unit Professional cleaning units established in accordance with the law are responsible. Professional cleaning units should sign cleaning contracts with users and publicize relevant information before cleaning. 9. Article 13 shall be regarded as the revised Article 15 and be revised to read: "Secondary water supply units shall clean and disinfect water supply facilities at least once every six months, and entrust qualified units to test water quality to ensure secondary water supply." The water quality of the water supply meets the national standards and can only be used after passing the test.
Secondary water supply units shall make public the water quality test results.
” 10. Article 16 shall be regarded as the revised Article 18 and shall be revised to read: “Professional cleaning units engaged in secondary water supply cleaning must implement the following provisions:
(1) Establish the user’s second File the cleaning data of water supply facilities and provide tracking services;
(2) After each cleaning and disinfection, a qualified water quality inspection department must be entrusted to take water samples for inspection;
(3) ) Upon receiving reports of secondary water supply water pollution from users who have signed cleaning contracts, they must immediately report to the municipal water administrative department and health administrative department, and send personnel to deal with it within 24 hours;
(4) Accept the supervision and inspection of the cleaning and disinfection of secondary water supply facilities by the water administrative department. "11. Delete Article 17. 12. Make Article 18 the revised Article 19, and modify the "health and family planning administrative department" in it to "the local health administrative department."