Advertising jingles about blood glucose meters

We often see promotional advertisements about blood glucose meters, so do you still remember what related advertising words? The following is the content I brought about about the publicity advertisement words about blood glucose meter, I hope it can let you have some harvest! The blood glucose meter publicity advertisement appreciation 1. a machine in the hand, blood glucose easily.

2. Small and extraordinary, unlimited affection.

3. My blood glucose I decide.

4. My blood sugar can?

4.

4.

5. My Fingerprint, your convenience.

6. Only use Fingerprint when you're out and about.

7. Anywhere, anytime.

8. Exquisite and compact, easy to carry.

9. Finley's life, with Jie companion.

10. With Finger in your hand, your blood glucose will be free from worry.

11. The Fingerprints. Gain control of your blood glucose.

12. A worry-free life with UPMG.

13. Convenient and fast.

14. The first thing you need to do is to take control of your blood glucose. The blood glucose is your blood glucose, and your heart is yours.

15. The best way to get the most out of your blood glucose is to take care of it. Gauge; live your life.

About Blood Glucose Meter

A blood glucose meter, also known as a glucometer, is an electronic instrument that measures blood glucose levels. Glucose meters are divided into two types, photoelectric and electrode, in terms of their working principle. Electrode-based glucose meters have a more scientific testing principle and the electrodes can be built-in.

Glucose meters are divided into two types from the working principle, one is photoelectric type and the other is electrode type. Photoelectric blood glucose meter similar to the CD machine, there is a photoelectric head, its advantage is cheaper, the disadvantage is that the detector head is exposed to the air, it is easy to be contaminated, affecting the test results, the error range of plus or minus 0.8 or so, the service life is relatively short, generally within two years is more accurate, two years later, it is recommended that the use of photoelectric machine patients to the maintenance station to do a calibration. General hospitals have hospital representatives to carry out regular maintenance, while the home blood glucose meter to the after-sales service department to carry out light maintenance.

Electrode-type testing principle is more scientific, electrode mouth inside, can avoid contamination, the error range is generally in the plus or minus 0.5 or so. High precision, no calibration is required for normal use, and long life.

There are two types of blood glucose meters from the blood collection method, one is the blood smear type, and the other is the blood suction type. The machines that wipe the blood generally take a larger amount of blood, which is more painful for the patient. If the blood collection is too much, it will also affect the test results, not enough blood, the operation will fail, waste of test strips, this blood glucose meter is mostly photoelectric type. Aspiration blood glucose meter, the test paper itself to control the measurement of blood samples, will not be because of the problem of the amount of blood results bias, easy to operate, with the test paper to point a drop of blood can be.

Now most blood glucose meters are broken type, is the need to take blood, for patients who need to measure blood glucose many times, there are no broken blood glucose meter came out, but the price is very high! In order to alleviate the pain of patients' fingertips blood collection, now introduced two arm blood glucose meter.

Sugar measurements are usually performed using the three-electrode system in electrochemical analysis. The three-electrode system, as opposed to the traditional two-electrode system, consists of a working electrode (WE), a reference electrode (RE), and a counter electrode (CE). The reference electrode is used to set the zero point, the current flows through the working electrode and the reference electrode to form a system that is not energized or basically less energized, and the stability of the potential of the reference electrode is used to measure the electrode potential of the working electrode. The working electrode and auxiliary electrode constitute an energized system, which is used to measure the current through the working electrode. The three-electrode measurement system is utilized to simultaneously study the relationship between the point potential of the working electrode and the current.

As a diabetic, monitoring blood glucose to understand the changes in blood glucose in the body can affect our entire treatment, and the error in how much is acceptable often becomes the focus of attention. The World Health Organization and the U.S. Food and Drug Administration, a number of data show that the blood glucose meter testing error within 20%, will not affect the patient's treatment plan, for example: three consecutive determinations of blood glucose, respectively, 6.4 mmol / l, 5.5 mmol / l5.9 mmol / l. Although the figures are not the same, but can see that the blood glucose control is good, and therefore do not have to change the treatment plan.

This is a characteristic of all blood glucose meters*** and is not a problem with any particular brand or meter. Patients measuring their own blood glucose often encountered different brands or the same brand of blood glucose meter between the inconsistent results of the problem, in fact, these are very normal, because the results of rapid glucose meter measurement is the range of values, each time the results of the measurement usually have some differences, but the difference will not be too big, rapid glucose meter with biochemistry instrument venous blood glucose between the error of no more than 20% are accurate, some patients on the instrument measurement data Some patients have problems in understanding the data measured by the instrument, thinking that the measurement data of the blood glucose meter should be the same as the blood glucose value measured through the vein, and if these two values are not the same, the quality of the product is problematic. But in fact, whether it is a home blood glucose meter or a hospital blood glucose measuring instrument, the measured value will not be the same every time, it should be said that the error value within ?10% of the blood glucose meter is very good, the general requirements of the error is not more than ?20%, there is no absolute correctness in this issue, only relative correctness. Of course, some of the wrong methods of measurement can also artificially affect the accuracy of the results.

People who watched the propaganda advertisement words about blood glucose meter also watched:

1. the propaganda advertisement words for selling medical devices

2. the classic immunohistochemistry medical device advertisement words

3. the classic advertisement words for watches

4. the advertisement words for Guomen Bay Building Materials Hardware City

5. the propaganda words about the electric wire Advertisement words