Does computerized intermediate frequency therapy device work?

Has excitation of neuromuscular. Analgesia, promote local blood circulation and other effects. \x0d\\\\x0d\\computerized intermediate frequency therapeutic instrument for therapeutic rehabilitation physiotherapy health care of an advanced medical equipment, this machine adopts the microcomputer control technology, composed of medium and large-scale integrated circuits, equipped with 8-way can be synchronized and asynchronous output channel, 4-way thermoelectric output channel, 2-way interference with the electric channel, 2-way ion introduction channel. \x0d\\\\x0d\1. Insert the net power connector on the power cord into the power input socket of the equipment on the electrotherapy machine and the plug into the fixed net power socket. \x0d\2.Place the electrode plate on the affected part of the patient, between the electrode plate and the human body should be dry towel as a mat, the thickness of which depends on the treatment site, generally 1-2cm. the more back the mat, the better the thermal effect of the deep tissue. The affected part should be placed between the two electrodes as far as possible when using the device. To prevent displacement of the electrodes, the electrodes and pads can be tied to the affected part with a dry bandage. \x0d\3. Select the "treatment time" (timer time) according to the treatment needs. \x0d\4.Turn the "Output Selection" to the "Preheat" position. \x0d\5. Will "power switch" from "off" to "on", "switch" green light on, machine The power supply is on, the electronic tube is lit, start to "warm up". \x0d\6. Turn the "power supply voltage adjustment" to 220V as indicated by the voltmeter. "Warm up" for two minutes. \x0d\7. "Output selection" rotary to "treatment 1" gear, then the yellow light, the machine began to work normally. The ammeter indicates the size of the oscillating tube screen current. \x0d\8. Turn the "output tuning", the ammeter indication also changes, when the resonance point is reached, the ammeter indication is maximum. Treatment is best done at the resonance point. \x0d\9. Depending on the need for treatment, different values of current can be selected. Such as "output selection" of the "1" gear is not enough dose, you can choose "2", "3", "4" gear. "4" gear to increase the dose. Each time you change gears, you should re-tune the unit so that it reaches resonance. \x0d\10.When the treatment time is up, the output is automatically cut off, the ammeter indicates zero, the "output selection" should be returned to the "preheating" in order to turn off the power supply, and then remove the electrode plate from the affected part of the patient. \x0d\11.If the machine needs to be used continuously, when replacing the patient, just rotate the "Output Selection" to "Preheat", the yellow light will not be on and the ammeter has no indication, then the patient can be replaced and the electrodes can be put in place and the above steps can be repeated. \x0d\12.This machine is equipped with a timer, with "normally open" and "timed" function. If you don't need the "timer", you can put the "treatment time" in the "normally open" place. If you need to control the "treatment time" automatically, you can place the "treatment time" at the desired position each time you use it, and then the output can be cut off automatically, and the machine is equal to return to the "preheating" state. After replacing the patient, only need to rotate the "treatment time", the machine has to restore the output.