Do you need to install emergency lighting in the living area of a construction site

Need.

According to the specification GB50016-2014 "Building Design Fire Prevention Code" 2018 edition:

I. In addition to residential buildings with a building height of less than 27m, evacuation lighting should be installed in the following parts of civil buildings, factories and category C warehouses:

1 closed stairwells, smoke-proof stairwells and their front rooms, fire elevator rooms Front room or shared front room, refuge aisle, refuge floor (room);

2 audience halls, exhibition halls, multi-purpose halls and building area of more than 200m_ business halls, restaurants, studios and other densely populated places;

3 building area of more than 100m_ of the underground or semi-subterranean public **** activities;

4 evacuation of the aisles within the building of public ****;

5 densely populated areas;

4 public buildings should be equipped with evacuation lighting. p>

5 Production places and evacuation aisles in densely populated plants.