Why the temperature of water-cooled chiller return water can not be higher than 40 degrees

Why the temperature of water-cooled chiller return water can not be higher than 40 degrees

Cooling water return temperature is higher than 40 degrees Celsius, then the temperature of the water will reach 45 or so, the higher the cooling water temperature, the higher the chiller exhaust temperature will also be higher, will be due to the exhaust temperature of the high thermal protection; general cooling water temperature control in the water inlet 35/water 40

Why not 40 degrees, the reason for the system does not have the

Why not 40 degrees high, the reason is not the system of refrigeration with, will be the low-pressure return air is too low, so that the compressor frost, reduce its service life. Of course, there are other working conditions.

Water-cooled chiller temperature does not come down how to do?

To inquire about the reasons why the temperature does not come down, targeted measures to improve the situation.

Generally speaking, the temperature does not come down, the unit cooling capacity deterioration, mostly due to insufficient water flow, the temperature difference between the water in and out of the water is too large, the water system pipeline is too dirty, the heat transfer effect deterioration and so on.

The need to implement the water-cooled unit according to the system's key state cited to roughly determine the cause.

Water-cooled chiller, chilled water temperature 4 degrees, inlet temperature 5 degrees What is the reason?

To see if the lack of refrigerant, heat transfer effect is not good, there is another situation is that the inside has been frozen, the water flow is slow

Water-cooled chiller 0 degrees when the low pressure is how much

1, according to the different refrigerants: R22 refrigerant water-cooled chiller 0 degrees out of the temperature of the water when the low pressure is 0.2 to 0.35 between;

2, R134a refrigerant water-cooled chiller 0 degrees water-cooled chiller with R134a refrigerant, the low pressure is between 0.1 and 0.25 when the water temperature is 0 degrees;

3, R410 refrigerant water-cooled chiller, the low pressure is between 0.3 and 0.4 when the water temperature is 0 degrees;

Screw water-cooled chiller is good

Screw water-cooled chiller is good, water-cooled screw chiller, I have a Kadeli chiller KDS-160DLA, seems to be twin-screw, good, almost three years. I have a KDS-160DLA chiller in my factory, which seems to be a twin-screw chiller! For your reference. Listen to the boss above to buy a, recently communicated technical aspects.

Industrial water-cooled chiller high pressure failure

Water cooler high pressure should be below 18KG. Your high pressure is too high, the current of the compressor will increase, the cooling capacity is reduced. The exhaust temperature will increase. Clean the condenser and cooling tower.

Which supplier of water-cooled chiller is good

Imported: McVicker, York, Trane, Daikin, etc.;

Domestic manufacturers are particularly large, the main need to consider the after-sales service and the cost of it

Water-cooled chiller, cooling water inlet temperature and chilled water outlet temperature on the efficiency of the unit's impact?

The lower the cooling water inlet temperature, the higher the outlet temperature, the greater the cooling capacity.

Chilled water is the opposite