Article I In order to strengthen the fire safety management of high-rise buildings, prevent and reduce fires, to protect national property and the safety of people's lives, according to the "Chinese People's Republic of China *** and the State Fire Services Ordinance", "Chinese People's Republic of China *** and the State Fire Services Ordinance Implementing Rules" and the Ministry of Public Security, "high-rise building fire management rules" and other relevant provisions, combined with the city's actual situation, the development of these provisions. Article III of this provision applies to be located in the city within the scope of ten (including ten) or more residential buildings (including the ground floor of the commercial service outlets set up residential) and building height of twenty-four meters (including twenty-four meters) above the other civil high-rise buildings. Article IV eliminate fire hazards in high-rise buildings, improve fire safety facilities, to ensure the safety of high-rise buildings, is the responsibility of each management and occupants. Article responsible for the new construction, expansion or alteration, renovation of high-rise building project design units must be in accordance with the national "high-rise civil building design fire code" standards and relevant fire safety laws and regulations, by the construction of the franchisee will be the project design drawings reported to the competent administrative department of urban planning and the public security fire safety supervision authorities for review and approval before construction. Article 6 After the completion of the new construction, expansion or alteration, renovation of high-rise building project, its fire protection facilities must be inspected and accepted by the public security fire safety supervision authorities before being delivered to the use; without acceptance or does not fully comply with the specifications of the project, no unit or individual shall not decide on their own to open for use. Article VII of the construction site of high-rise building fire management by the construction unit and the construction unit to sign a management contract, clear responsibilities, and reported to the public security fire safety supervision authorities for the record; construction period of fire safety work, by the contractor is responsible for the organization and implementation. Article VIII of the construction of high-rise buildings and fire fighting water supply should be synchronized in place, and to ensure that the effective range of fire fighting water supply is not less than thirteen meters. Article IX of high-rise buildings, interior decoration materials, shall not arbitrarily reduce the fire resistance level; used for ceiling, inter-wall, thermal insulation and muffling must be non-combustible or flame-retardant materials. Article 10 The installation of electrical facilities in high-rise buildings should be strictly in accordance with the national "Building Electrical Design Technical Regulations" and "Guangzhou Electrical Equipment Installation Regulations". The top of the boring, mezzanine and other hidden wires must be set into the metal pipe, the wire head must be insulated and installed into the junction box closed; electrical equipment, lightning protection facilities, safety conditions and line insulation should be checked frequently; spring and fall seasons each year, a test must be carried out, and faults should be found in a timely manner to be ruled out. Article XI of high-rise buildings shall not be haphazardly connected wires. For maintenance needs to set up temporary wires, must be reported to the unit responsible for fire approval, the use of temporary wires shall not exceed half a month, the expiration date should be removed. Article XII of high-rise buildings, warehouses, offices, every day at the end of the day must close the doors and windows, clean up debris, cut off the power supply. Article XIII of high-rise buildings, hotels, buildings, hotels, restaurants and other guest rooms, prohibit the use of electric stoves, electric irons, soldering irons and other electric appliances. Office buildings and part of the housing used as offices do need to work for the installation of photocopiers, teletype machines, computer typewriters and other equipment, should be approved by the public security fire safety supervision authorities. Article XIV of air conditioning with the air supply and return ducts should not cross the firewall. If there is a need to cross the firewall, firestopping devices must be installed. Article XV of high-rise public **** building does require the use of temporary open-flame operations, must strictly implement the fire approval system, and seriously comply with the safety of fire regulations. Article XVI of the building is prohibited to store flammable and explosive chemical hazardous substances. Indeed, because of teaching, scientific research, medical and other necessary and daily use does not exceed twenty kilograms, can be categorized and stored in separate warehouses for three to five days of the amount, and fixed, fixed point, fixed measures to be properly stored. Article XVII is strictly prohibited in high-rise buildings, storage, sales, fireworks.
High-rise buildings, guest houses (travel), hotels shall not store and use bottled liquefied petroleum gas. Has not yet adopted the pipeline gas supply high-rise building residential use of bottled liquefied petroleum gas, each household is allowed only a limited bottle; and must be equipped with fire extinguishing equipment, prohibit the use of gas stove room at the same time as the use of other open-flame stoves. Article XVIII fume pipe, chimney must be regularly cleaned and maintained, cleaned up every six months no less than once; chimney fume pipe corner cleanup every quarter no less than once; fume hood mouth cleanup every week no less than once. Article 19 The fire engine access around high-rise buildings shall not be blocked or occupied; stacking of objects in the access and entrance of each floor is strictly prohibited. Article 20 The densely populated public **** places must have more than two entrances and exits in different directions, and set up emergency evacuation signs and accident lighting devices in conspicuous and easily visible positions at the entrances and exits. Article 21 high-rise hotels, hotels shall be installed on all floors of the emergency evacuation broadcasting equipment, and should be equipped with emergency life-saving appliances, guest rooms must have a safe evacuation of the line instruction map. Article 22 Where in the "high-rise civil building design and fire code" published before the implementation of the construction and use of high-rise buildings, their management units should be checked against each item, the fire hazard potential and imperfect fire safety facilities, must be made to rectify the plan, reported to the public security fire safety supervision authorities for the record, and in the deadline for completion of the rectification. Article 23 The high-rise building must be in accordance with the provisions of the "high-rise civil building design and fire code" device fire water supply system; hydrant box additional fire hose reel, hose range should be able to reach any part of the interior, but the length of the hose shall not exceed thirty meters.