What is a negative pressure isolation chamber?

Negative-pressure isolation compartment, is a small movable emergency safety isolation protection device with the function of blocking the source of infectious diseases, can provide temporary isolation space for feverand suspected patients at the scene in a timely manner, rapid and safe isolation, and effectively reduce the spread of the virus carried by the fever and the suspected patients to the outside world, contamination of the environment.

Features:

1, using negative pressure exhaust purification technology, high-pressure electrostatic field capture + ultraviolet disinfection + activated carbon filtration, the cabin air disinfection and purification after discharge. Cabin air change more than 30 times per hour, virus killing rate of 99.99%, sterilization rate of 99.99%.

2, the cabin is also equipped with infrared temperature detection device, can dynamically monitor the cabin temperature of the isolated personnel, and displayed in the cabin outside the LCD screen.

3. It can realize remote operation and control of mobile client and PC terminal, as well as statistical report of big data platform.

4. Cameras are installed in the passenger cabin, which can be connected through 4G network to realize remote dynamic management of managers.

5. The cabin is equipped with a call intercom and emergency alarm system, which allows isolated personnel to remotely realize intercom and emergency alarm with managers.

6. The security transmission window can provide items for the isolated personnel.

7. The cabin is equipped with ultraviolet disinfection lamps, which can disinfect the interior of the cabin and the transfer window in time when no one is present.

8. The isolation cabin is equipped with UPS uninterruptible power supply, which can realize charging or normal power supply for 3 hours when the external power supply is interrupted.

9, the cabin design adopts warm type and installs TV system to fully release the pressure of isolation personnel.

Precautions for use:

1, the used negative pressure isolation stretcher should be cleaned and sterilized in time.

2, please put the negative pressure isolation stretcher in a cool and dry place.

3, standby and use before attention to timely charging. Please calculate the time after power outage and don't forget to charge it in time after use to be ready for the next use.

4, When the filter membrane of the air inlet becomes dirty, please replace it with a new one in time.

5, after a period of use, when the negative pressure is not formed in the isolation room, please replace the hePA filter of the exhaust system. Negative pressure isolation stretcher can not be long exposure to the sun and wind and rain, should be stored in the shade. Keep the negative pressure isolation stretcher clean.

6. Please be careful when disassembling and installing, so as not to scratch the shell structure of the negative pressure isolation chamber.

7. When transporting patients, please do not open the zipper at the entrance of the patient to avoid leakage of disease sources.

8. If there is any problem in use, please feel free to contact the safety technician.