Legal analysis: bag standards
1, bags shall not use polyvinyl chloride (PVC) plastics as raw materials for manufacturing;
2, polyethylene (PE) bags shall not leak, rupture, perforation of normal use;
3, the maximum volume of 0.1m3, the size and shape of the moderate, easy to handle and cooperate with the turnover box (drum) Shengshuo;
4, if the use of linear low-density polyethylene (LLDPE) or low-density polyethylene and linear low-density polyethylene ****, the maximum volume of medical waste packaging standards. p>
4, if the use of linear low-density polyethylene (LLDPE) or low-density polyethylene and linear low-density polyethylene **** mixed (LLDPE + LDPE) as raw materials, the minimum nominal thickness should be 150μm; if the use of medium-density or high-density polyethylene (MDPE, HDPE), the minimum nominal thickness should be 80μm;
5, bags of The color is yellow, and has a text description of the type of medical waste, such as infectious waste, should be added to the bag "infectious waste";
6, the bag should be printed on the medical waste warning signs identified in Article 5 of these provisions.
Legal basis: "Medical Waste Special Packaging, Container Standards and Warning Labeling Provisions" Article 3 Sharps Box Standards
1, the sharps box as a whole is made of hard materials, sealed to ensure that the sharps box in the normal use of the box, the box contains sharp instruments do not leak, sharps box once sealed, can not be reopened without destroying the case;
2, the sharps box can prevent puncture, its holding syringe needles, broken pieces of glass and other sharp instruments can not pierce the sharps box;
3, the full amount of sharps box from a height of 1.5m vertical drop to the concrete floor, 3 times in a row, the sharps box will not appear rupture, puncture and so on;
4, the sharps box is easy to incinerate, shall not be used as the manufacture of polyvinyl chloride (PVC) plastic Raw materials;
5, the overall color of the sharps box is yellow, in the box on the side of the "injurious waste";
6, the sharps box should be printed on the provisions of the fifth article determined by the warning signs of medical waste;
7, the sharps box specifications and dimensions can be determined in accordance with user requirements.