specially designed for large OEM
size: 3.8mm×1.31mm
temperature accuracy: sht1: .4℃
sht1l: .5℃
humidity accuracy: sht1.
application field: humidifier/dehumidifier
HVAC
electronics industry
weather station, etc.
-----------.
-humidity measuring range: ~ 1% RH;
-humidity measuring range:-4 ~+123.8℃;
-humidity measurement accuracy: sht1: 4.5% RH
sht11: 3% RH
sht15: 2% RH
-temperature measurement accuracy: sht1: .5℃
sht11: .4℃
. 4s;
-low power consumption (typ. 3? W)
-completely submerged.
application field:
data collector
transmitter
automatic process control
automobile industry
building control &;
measurement test of HVAC
power
pharmaceutical industry
please refer to the data sheet
-----------for details. Welding-free, convenient for customers to use
- measuring range: -1% RH
- humidity measuring accuracy: +/- 4.5% RH
- temperature measuring accuracy: +/- .5℃@25℃
- completely calibrated & Digital output (2-wire digital interface)
- fast response <; 4 sec.
- low power consumption (typ. 3? W)
- lowest cost
- leading CMOSens? Technology, excellent long-term stability
- fully calibrated, digital output, easy to use and develop
Application fields:
- data collector
- transmitter
- automatic process control
- automobile industry
- building control & HVAC
- Electric power
- Metrology test
- Pharmaceutical industry
For details, please refer to the datasheet
------------.
-full range calibration, two-wire digital output;
-humidity measuring range: ~ 1% RH;
-humidity measuring range:-4 ~+123.8℃;
-humidity measurement accuracy: sht71: 3.% RH
sht75: 1.8% RH
-temperature measurement accuracy: sht71: .4℃ (@ 25℃)
sht75: .3℃ (@ 25℃). 4s;
-low power consumption (typ. 3? W)
-completely submerged.
application field:
data collector
transmitter
automatic process control
automobile industry
building control &;
measurement test of HVAC
power
pharmaceutical industry
please refer to the data SHT1x
-----------for details.
- dustproof, waterproof and other pollutants
- protection level: IP67
- simple installation method
application field:
-HVAC
- automobile
- test and measurement
- medical treatment
Please refer to datasheet
-
-manufactured by SHT11 and SHT15 of Sensirion Company;
-humidity measurement range: 1 ~ 99% RH;
-humidity measuring range:-4 ~+123.8℃;
-the highest humidity measurement accuracy can reach 2.5%RH;;
-the highest temperature measurement accuracy can reach .3℃;
-installation method: equipment embedded;
-signal output mode: standard voltage (-1V,-5V or other user-defined forms)
For details, please refer to data sheet
----------.
-humidity measuring range: ~ 1% RH;
-humidity measuring range:-4 ~+123.8℃;
-humidity measurement accuracy: 4.5% RH
-temperature measurement accuracy: .5℃
-response time: <; 4s;
-low power consumption (typ. 3? W)
-completely submerged.
application field:
data collector
transmitter
automatic process control
automobile industry
building control &;
measurement test of HVAC
power
pharmaceutical industry
for details, please refer to data sheet
----------------------.
-humidity measuring range: ~ 1% RH;
-humidity measuring range:-4 ~+123.8℃;
-humidity measurement accuracy: 3.% RH
-temperature measurement accuracy: .4℃
-response time: <; 4s;
-low power consumption (typ. 3? W)
-completely submerged.
application field:
data collector
transmitter
automatic process control
automobile industry
building control &;
measurement test of HVAC
power
pharmaceutical industry
for details, please refer to data sheet
----------------------.
-humidity measuring range: ~ 1% RH;
-humidity measuring range:-4 ~+123.8℃;
-humidity measurement accuracy: 2.% RH
-temperature measurement accuracy: .3℃
-response time: <; 4s;
-low power consumption (typ. 3? W)
-completely submerged.
application field:
data collector
transmitter
automatic process control
automobile industry
building control &; Hvac
electric power
measurement and testing
pharmaceutical industry