Nucleic acid collection point setup requirements

Nucleic acid collection point setup requirements

Sampling point selection of open, cool and ventilated site, set up a temporary tent, away from crowded areas, conducive to ventilation, medical personnel sampling should be in the upwind direction.

Sampling point set partition. Sampling point should choose an open, well-ventilated site, divided into waiting area, collection area, buffer zone, temporary isolation area and medical waste storage area, effectively dispersing the density of people to be examined.

(1) Waiting area. Set up pedestrian access, while setting up a safe distance to ensure the protection of waiting personnel safety. According to the weather conditions, equipped with heat preservation, cooling, shade, rain and other facilities.

(2) collection area. According to the weather conditions, equipped with tents, cold / warm fan, appropriate amount of tables and chairs. Equipped with collection of disinfection supplies, swabs, virus collection tubes, and should be prepared for the person being collected paper towels, vomit bags and masks spare. If the specimen cannot be transported to the laboratory in time, a 4℃ refrigerator or cryopreservation box should be prepared for temporary storage.

(3) buffer zone. The space should be relatively confined, can be sampling personnel to change personal protective equipment, placed with the size of the sampling site to match the protective equipment, collection of disinfection supplies, swabs and collection tubes, outdoor extermination equipment.

(4) temporary isolation area. Used for temporary isolation of suspected patients or high-risk groups found during the collection process.

(5) medical waste temporary storage area. Used for temporary storage of medical waste, and do a good job of collection, packaging, harmless treatment, handover and so on.