What are the types of medical air sterilizers?

Medical air sterilizer in the provisions of the design of indoor space within the scope of the air there are hazardous gases, germs and other toxic objects to make every effort to clean, regardless of how the outdoor gas standards change, can ensure that the cleanliness level required in the room. The more common medical air sterilizers on the market today mainly include ozone air sterilizers, ultraviolet air sterilizers, nano photocatalytic air sterilizers, low-temperature plasma air sterilizers, so what are the types of medical air sterilizers? What are the precautions for the use of medical air sterilizers? The following and we take a look ~

Medical air disinfector what type

1, ozone air disinfector

Ozone disinfector in the ozone generator is the most important with the help of electrolysis method production into the production of ozone generator, usually large and medium-sized categories of ozone generator is generally divided into the source of O2 and its air, and the air can heat pump two types, choose to use the instantly, and the air can heat pump. Ozone generators are usually divided into two types: O2 sources and air heat pumps, which are used to produce ozone by electrolysis of O2 in an immediate manner. The ozone generated by the ozone generator in the lower concentration of the conditions can be in a very short period of time to carry out chemical action; when in a very small amount of the phenomenon will have a refreshing breath.

2, ultraviolet air disinfector

Principle of ultraviolet disinfector work, through the ultraviolet light for gas germs and viruses and other microbial strains of bacteria to carry out direct, in order to promote the body of the body's existing DNA components caused by the destruction of the effectiveness of the body, so that they can be the death of the death of the breeding capacity to carry out the lack of.

3, nano photocatalyst air disinfector

Often the use of nanotechnology categories of nano-photocatalyst raw materials, with the violet-colored light effect of direct radiation to carry out the mutual cooperation, resulting in titanium dioxide surface containing positive electrons of the cavitation and negative electrons containing negative ions in the air.

4, low-temperature plasma air sterilizer

Decontamination principle, is the use of plasma electric field with bipolar will contain negatively charged germs caused by the dissolution and defeat of the effect of the dust in the gas to carry out hit and its suction, and then and the matter of the pre-pregreg activated carbon and its static electricity network and nano photocatalyst blowing equipment and other categories of components to do the second decontamination, according to the treatment of the clean gas to carry out a large number of rapid circulation. The clean gas carries out a large number of rapid circulatory system fitness exercise, and makes the natural environment under control in the absence of germs and dust and other norms.

What are the precautions to be taken in the use of medical air sterilizers

1. Whether it is used for static data sterilization or dynamic continuous sterilization, the windows must be closed.

2. It is strictly prohibited to conceal or block the air inlet and vent.

3. Power plug must be used with a safety ground three-pronged power outlet.

4. Water seepage from the internal structure of the equipment is strictly prohibited. When cleaning the equipment with a wet rag, you must first disconnect the switch power.

5. In order to achieve sterilization efficacy, can not be applied over the volume.

6. Check the working condition of the machine on time. If there is an abnormality, it should be repaired immediately, and common malfunctions of household appliances should be solved by professional technology.

Medical air sterilizer protection and maintenance of key points

1. Filter protection: check the filter on time, if too much dust is found on the filter, please rinse with tap water or replace it immediately. When replacing, open the back cover of the filter device, remove the filter from the device and replace it with a new one, and cover the back cover.

2. UV light tube maintenance: UV intensity will affect the indoor disinfection efficacy. Therefore, at least once a month with alcohol cotton wool scrub UV light tube to ensure that the irradiance of the UV light tube will not be affected by dust.

3. The protection of negative air ions generator: because of the negative air ions of the dust reduction effect, after a long period of time, Dali dust will accumulate in the vent shell around, so it should be regularly cleared. Cleaning, first of all, should be disconnected from the switch power supply, with a soft dry

book or a little alcohol scrubbing. Note: Do not clean with tap water. Body sensing probes and displays can not be scrubbed with all cleaning fluids, alcohol, etc., and can only be scrubbed quietly with a sticky cloth.