What is the permissible deviation of verticality of prefabricated cement mixing pile in construction project?

Pile position deviation allowed (full pile≤0.40D, strip foundation pile≤0.25D); verticality deviation allowed ≤1.5%; column hammer punching and expanding extruded rubble pile: pile position deviation allowed ≤50mm; verticality deviation allowed ≤1.5%; reinforced concrete precast pile: verticality deviation allowed when inserted into the soil ≤0.5%; permissible deviation of pile position (1~3 piles≤100mm; 4~16 piles≤D/2; more than 16 piles, side piles ≤D/3, intermediate piles D/2); with pile roof beam, along the beam, with pile top beam, and with pile top beam, with pile top beam, with pile top beam, with pile top beam, with pile top beam, and with pile top beam, with pile top beam, with pile top beam. There are pile top beams, ≤150+0.01H mm in the direction of beam axis, ≤100+0.01H mm in the direction of vertical beam axis); concrete bored piles: permissible deviation of pile position (1~3 piles, single row lateral, group piles of side piles ≤70mm; single row axial, group piles of intermediate piles ≤150mm); permissible deviation of verticality ≤1.0%; where: D is the diameter of the piles; H is the height of the top of the pile to the ground; There are many more, tell you so much first.