1. The timer of disinfection cabinet equipment is broken. Generally speaking, the disinfection time of the disinfection cabinet is fixed. If the disinfection time exceeds the specified time and the temperature exceeds 100 degrees, it means that its timer is broken. At this time, people can manually turn off the power switch of the disinfection cabinet. After that, people had better find professional maintenance personnel to replace the timer.
There are too many tableware in the disinfection cabinet. If people put in too many tableware, which exceeds the requirements of the disinfection cabinet, it may affect the normal work of the disinfection cabinet, that is, the equipment will continue to work when it detects that the disinfection work is not completed. In this case, there is no need for maintenance, and people just need to put in an appropriate number of tableware.
3. There is something wrong with the circuit board of the disinfection cabinet. When the circuit board of the disinfection cabinet fails, its disinfection time will also be extended. This situation also requires a maintenance master to come to the door for maintenance.
How to use the disinfection cabinet correctly?
1. It is best to clean the disinfection cabinet once every three months or half a year, so that it can be used for a long time.
2, different tableware, disinfection methods are different, people should choose disinfection methods according to the types of tableware, disinfection effect will be the best. For example, plastic tableware should be placed in ozone disinfection space, while aluminum alloy tableware can be disinfected at high temperature.
3. The disinfection cabinet must be laid flat, away from the fire source. Don't move it often.
4. Don't open the disinfection cabinet immediately after disinfection, because the internal temperature is still relatively high, and it will burn if you are not careful. In general, people had better open the disinfection cabinet after half an hour.
It's best to wait until the water in the bowl is completely dry before putting it into the disinfection cabinet to avoid water stains when water drops fall into the disinfection cabinet. At the same time, water droplets will cause the metal parts of the disinfection cabinet to be oxidized by moisture, which will easily burn out lamps and other parts, and eventually lead to the shortened service life of the disinfection cabinet.
6. When disinfecting tableware, people should never open the disinfection cabinet, so as not to affect its disinfection effect.