I. Bidding number: WCZFCG-09-E-242
II. Bidding content
1. Project name: Wuhan Municipal Family Planning Commission medical equipment government procurement project
2. Scope of procurement: to provide the corresponding goods in accordance with the technical requirements of the products required by the purchaser, and complete the transportation of all goods, installation and commissioning and related services.
3. There are 9 packages in this tender project ***, each bidder can bid for one or more of the following packages.
Package No.
Equipment Name
Main Technical Specification Requirements
Quantity
Budget
01
Portable Mammography Instrument
1, ? Camera: original imported CCD camera, minimum illumination: 0.05Lux, resolution: ≥ 600TVL; image gray scale degree: 256 levels?8Bit A/D; focal length of 0.25m ~
2.? Video signal output: amplitude 1Vp-p, impedance 75Ω;
3.? Analog signal input: standard TV signal 1Vp-p input, 525 lines/field or 625 lines/field;
4. Display color: 8 sets of standard color coding and user-defined color step coding; system image resolution ≥ 500TVL;
6, Display: ≥ 15″ LCD monitor;
7, Probe: infrared wavelength: 0.8μm ~ 1.5μm; Probe's optical power of 0.2W ~ 1W continuously adjustable; Probe's output illuminance: 0 ~ 10000Lx continuous Adjustable; probe beam diameter: 14 ± 1mm; probe regulation: electronic stepless dimming.
8. Cold light bulb power: 24V?150W
9. Light source transmission mode: soft optical fiber
10, input power: ≤ 350 VA;
11, wide voltage design: working range AC130V-270V?50HZ ± 1HZ;
12, continuous working time ≥ 24 hours;
13, the type of instrument: Ⅰ B-type general equipment;
1
18000
02
Portable electronic colposcope
1, ? Electronic lens: photoelectric digital color CCD, using SONY1/4type Exview HAD CCD module;
2,?CCD pixels: more than 480,000 pixels;
3,? Horizontal resolution: greater than or equal to 470 lines of horizontal resolution lines;
4.? Laptop: host configuration Intel?PM1.3GHZ?CPU.1G?DDR memory, 160G hard disk, SONY?COMBO CD-ROM drive, NEC 17-inch LCD monitor;
5.? Printer: HP Color Inkjet Printer Series;
6,? Magnification: optical 1--18 times, digital 19--28 times, infinitely continuous amplification;
7. Signal-to-noise ratio:50dB
8. Depth of Field:5mm--120mm;
9. Field of view:10mm---60mm;
10, Effective operating distance:1-6 times:170---300mm,7-28 times:220---300mm
1
30000
03
Laptop digital electronic colposcope
1, lens clarity: SONY original high-resolution, high-definition color digital CCD camera, resolution ≥ 480,000 pixels, 1/4-inch color digital CCD.
2, resolution: more than 470 lines, F1.4, 4-64 optical zoom lens.
3, lens depth of field: 100 ~ 350mm.
4, field of view: φ = 2.5 ~ 250mm.
5, lens focusing distance: 300 ~ 1,000mm.
6, lens illuminance: greater than 1400Lux.
7, lens magnification: optical 16 times, digital 26 times. Image clear magnification 128 times, the highest 220 times.
8, lens focus mode: DSP dynamic auto-focus system, automatic white balance, color digital restoration, with manual focus adjustment.
1
17000
04
Infrared Mammography
Camera Minimum Illumination: 0.001Lux, Focal Length: ?25mm, Resolution: ≥600TVL, Illumination: 0~1.0×105Lux, Beam Diameter: 14mm, Probe Temperature Rise: ≤6°C
1
9000
05
Blue Oxygen Therapeutic Instrument
Working Mode:* Instantaneous, continuous work
*Ozone flushing, ozone nebulization, red light constant heat intracavity therapy can be used simultaneously
Time Control: flushing: 5-20 minutes adjustable
Nebulizing: 5-15 minutes adjustable
Temperature Control: 0~1 × 105Lux, beam diameter: 14mm, probe temperature rise: ≤6℃
Temperature control: rinse: 25 to 40 ℃ adjustable
nebulization: room temperature
*Self-setting treatment time, storage of the number of times of use, with the treatment management function
*Self-heating water supply system, the temperature of 25 ℃ to 40 ℃, and tap water filtration system
*Automatic filling of nebulization system, water shortage alarm
Volume: 650mm*480mm*1000mm(L*W*H)
Weight: 26kg
*650 red light constant heat intracavity probe: wavelength: 650nm?
1
70,000
06
Breast therapeutic instrument
l) original imported CCD camera. Resolution: ≥600TVL, the minimum illumination of the camera work: 0 001Lux, 105
Image gray scale 256 levels
2) light source maximum illumination 1 × 105LuX stepless adjustable
3) Probe photoconductive; brightness stepless adjustable, the maximum output is not less than ?0.2W, not more than 1w
4) wide voltage design : Operating range AC?130V-270V?50Hz±1Hz
5) Continuous operating time of ≥ 24 hours
6) Video signal output: IVp-p: Impedance: 75Ω
7) Configuration: High-definition, 17-inch flat screen display. Real-time dynamic color display, high-quality color inkjet printer, foot switch
6
22000
07
Surgical bed
Tabletop length and width 2060?L × 500?L, tabletop minimum and maximum height 800?L × 1050?L
Tabletop left tilt ≤ 16?L, right tilt ≤16?, front tilt of the table top ≤20?, back tilt ≤20?, head folding angle upward ≤50?, downward ≤90?, footboard folding angle downward ≤90?
1
30,000
08
Active Blood Pressure Cardiology Monitor
Exterior: 12.8 x 7.8 x 67.5px
Weight: 250g (including battery)
Measurement method: Oscillometric method
Measurement time: 30-50s
Accuracy: ±5mmHg
Storage range: 300 values
*1.1Original imported 24-hour monitoring ambulatory ECG recorder
1.2Power supply requirement: 220v ± 10%,50-60Hz or wider
1.3 Main functions: with heart rate arrhythmia analysis, heart rate variability analysis, enhanced ST analysis, pacemaker analysis, QT period analysis, etc.
1
250000
09
Portable ultrasound
2.1?Monitor ≥ 10.4 inches High-brightness color LCD monitor
2.2?Safety performance in line with the State Drug Administration Commodity Safety and Quality Requirements
2.3?Probe specifications
*2.3.1?Frequency wide-band or variable frequency probe, variable frequency probe center frequency can be selected ≥ 3 kinds of color and Doppler can be selected from a different frequency respectively
2.3.2 type
2.3.2.1?Intracavity probe type ≥ 2 types
2.3.2.2?High frequency probe center frequency ≥ 7.5MHz
2.3.3 Convex array probe effective number of oscillators? ≥128 oscillators
2.3.4B/D both
2.3.4.1?Line array B/PWD
2.3.4.2?Convex array B/PWD
*2.3.4.3Phased array?B/PWD/HPFF
1
250,000
III. Necessary Qualifications for Qualified Bidders
1. Bidders must meet the conditions stipulated in Article 22 of the Government Procurement Law of the People's Republic of China*** and the State, and have the ability to provide all procurement contents under the contract.
2. The registered capital of the bidder shall be not less than 500,000 RMB.
3. The bidder must have a medical device production or business license; the bidder's proposed product must have a medical device registration certificate and medical device registration form issued by the State Drug Administration.
4. The bidder shall have a perfect after-sales service organization in the local area, which can provide emergency service of spare parts and localized technical service of the equipment of this tender. If the bidder does not set up after-sales service network in Wuhan, it must entrust the agent with corresponding qualification conditions in Wuhan to provide after-sales service, and provide the commissioning agreement between the two parties (submit the original), the commissioned person's business license (the registered capital should be not less than RMB 500,000 yuan) and the tax registration certificate, the contact person and the contact phone number and other information.
Four. Bidding matters
1. Any bidder who is interested in participating in the bidding of this project and meets the above conditions may apply for registration to the centralized purchasing agency, and only qualified bidding applicants may be invited to participate in the bidding.
2. Application time and place: December 11, 2009 onwards daily 8:30 am - 12:00 and 15:00 pm - 17:30 (Beijing time, except double holidays and holidays) in the centralized purchasing agency to apply.
3. Registration materials include a certificate of identity of the legal person; legal person power of attorney and the identity card of the delegate; business license of the enterprise legal person; tax registration certificate; legal person organization code certificate; the registration certificate of the medical device of the product; and other relevant qualification documents; similar project performance documents; and other documents that the bidder believes that need to be provided. All of the above information must be provided in original. Bidders are required to provide the registration form, the registration form is attached below the announcement.
4. Bidding documents on sale: December 12, 2009 onwards daily 8:30 am - 12:00 pm and 15:00 pm - 17:30 (Beijing time) except for double holidays and holidays, at the Wuchang District Government Procurement Center, the price of each set of RMB 50 yuan, non-refundable. If mail order is required, please contact the centralized purchasing agency by fax, and the postage fee is RMB 50 yuan per set.
5. Deadline for submission of bidding documents: 9:30AM (Beijing time) on December 24, 2009
6. Opening time: 9:30AM (Beijing time) on December 24, 2009
Place of opening: Room 605, China Railway Building, No. 347, Zhongshan Road, Wuchang District, Wuhan City
7. This item has entered into the government procurement procedure, if you have any objection, please challenge the purchaser and the centralized purchasing agency. If you are not satisfied with the response to the challenge, file a complaint with the finance department at the same level within 15 working days after the expiration of the response period.