Power supply accuracy grade standard for medical equipment

Main features:

& gt& gt accuracy levels: 0.2 and 0.5. The product has been inspected and corrected before leaving the factory, and users can use it directly.

> > auxiliary power supply: 5V/ 12V/ 15V/24VDC (range 10%).

> > PWM pulse width modulation signal input: 50Hz~ 100KHz.

& gt& gt output standard signals: 0-5v/0- 10v/ 1-5v, 0-10ma/0-20ma, etc. , high load capacity.

& gt& gt Extremely high linearity (nonlinearity

& gt& gt standard DIN35 guide rail installation

& gt& gt has strong ability to resist electromagnetic interference and high frequency signal interference.

Application:

DA conversion from digital signal to analog signal

& gt& gt isolate 4-20mA or 0-20mA signal transmission.

Isolation and conversion of special signals in industrial field

Long-line lossless transmission of>& gtPWM signal

& gt& gt instrument signal transceiver

& gt& gt Power Monitoring and Medical Equipment Isolation

& gt& gt frequency converter signal isolation acquisition

Signal isolation control of PLC/FA motor

> > pulse width measurement

Select an example:

Example 1: input signal: 100Hz PWM power supply: 24V output signal: 4-20mA model: din11ibfpwm2-p1-a4.

Example 2: input signal: 5KHz PWM power supply: 12V output signal: 0- 10V model: din11ibfpwm3-p2-v2.

Example 3: input signal: 20KHz PWM power supply: 24V output signal: 4-20mA Model: DIN11IBF PWM 4-P1-A4.

Maximum absolute rating of the product:

Continuous isolation voltage: 3000VDC.

Junction temperature: +85℃

Storage temperature:+150℃

Lead temperature: +300℃( 10 second)

Power supply voltage range: 10% vin

Note: If it exceeds the above range, the product may cause permanent damage.