What instruments are needed for environmental testing?
Environmental monitoring instruments include: atmosphere, occupational health, noise, vibration, radiation detection instruments.
Atmospheric environmental monitoring instruments:
1, atmospheric sampler: for ambient air, workplace sampling of toxic and hazardous gases, formaldehyde, ammonia, TVOC, benzene and other samples
2, particulate matter sampler: capture the ambient atmosphere of the total suspended particulates and respirable particles or fine particles
3, atmospheric particulate matter composite sampler: collection of environmental Atmosphere, indoor air in a variety of harmful gases, capture the total suspended particulates and respirable particles in the ambient atmosphere
4, air fluoride sampler: for environmental fluoride and heavy metal collection
5, volatile organic compounds sampler: ambient air sampling of volatile organic compounds, adsorption tube method
6, precipitation and dust precipitation sampler: with snow melting, refrigeration, snow melting, water precipitation, dust precipitation, dust precipitation, water precipitation, dust precipitation, dust precipitation, dust precipitation, water precipitation, water precipitation, dust precipitation, dust precipitation, dust precipitation, dust precipitation, dust precipitation, dust precipitation, dust precipitation Dust precipitation, precipitation
7, soap film flow meter: calibration of small flow sampler, range optional
Occupational health testing instruments:
1, atmospheric sampler: low-flow, medium-flow, high-flow sampling of different flow requirements of the instrument
2, explosion-proof atmospheric sampler: used for the collection of gas samples of the routine instrument in the explosive atmosphere
3, dust sampler: dust sampler: ambient air sampling of VOCs, adsorption tube method. p>3, dust sampler: the collection of dust in the air at the workplace sampling instrument p>
4, explosion-proof dust sampler: suitable for explosive hazardous gases in the operating environment dust sampling p>
5, soap film flow meter: to meet the requirements of different flow rate sampling p>
6, radiant calorimeter: a direct measurement of the radiant heat temperature, air and skin temperatures, the directional average radiant temperature p>
6, radiant heat meter: directly measuring the radiant heat temperature, air and skin temperature, directional average radiant temperature p>
7, the temperature of the air and skin temperature, the average radiant temperature < /p>
7, illuminance meter: light intensity measurements
8, WBGT index meter: used to evaluate the meteorological conditions of the high temperature workshop, which takes into account the air temperature, air humidity, wind speed and radiant heat four factors.
9, anemometer: for any place so measure wind speed, temperature and relative humidity
10, dust detector: dust concentration detection instrument
11, explosion-proof dust detector: determination of ambient air concentration of floating dust instrument, used in coal mines and other workplaces containing explosive hazardous gases
Noise Detection Instruments:
1, noise detector: the instrument to test the noise decibel
2, individual noise dosimeter: personal acoustic exposure measurement
3, explosion-proof noise detector: petroleum, chemical industry, oil depots, iron and steel, coking, coal and other explosion-proof places of the noise detection
Vibration Detection Instruments: environmental vibration detector, mechanical vibration detector, multifunctional vibration analyzer, Hand transmission vibration tester
Radiation detection instruments:
1, electromagnetic field tester: measuring 1Hz-100kHz electromagnetic field, high frequency, ultra-high frequency, microwave equipment
2, field strength meter: mainly used to measure the high-voltage transmission and transformation systems, distribution rooms, induction furnace, subway, electric locomotives, medical equipment, drying equipment, computers and other electromagnetic radiation with the operating The magnetic field strength of the place
3, personal dose alarm: used to monitor X-rays and γ-rays
4, neutron dosimeter: used for neutron dose rate detection
5, х γ radiation detector: measurement of high-energy, low-energy γ-rays, but also low-energy X-rays to carry out accurate measurements
6, radon meter: measurement of soil radon, radon, radon air, radon in the water concentration and radon precipitation rate, and the rate of radon precipitation. and radon precipitation rate, to meet the new national standard
7, low background αβ meter: αβ meter
8, αβγ surface contamination meter: for radioactive surface contamination measurement, can be measured simultaneously on the α, β, γ rays
Which manufacturer produces a good dust detector?
At present, the domestic standard dust concentration detector is Shenzhen Sainavi manufacturers, mainly CW-76S automatic dust concentration detector, the instrument is Sainavi independent research and development set of aerodynamics, digital signal processing, photoelectricity, integration of high-tech products, mainly used to detect the atmospheric concentration of dust quality, applicable to construction sites, urban grid monitoring, mobile monitoring and other fields It is the core module of the atmospheric quality detection system.
How does the dust detector work? What is the principle?
Dust detector referred to as dust meter, also known as dust meter or dust tester, is mainly used to detect the dust concentration in the ambient air, the type of dust meter is divided into: laser dust meter, on-line continuous monitoring of dust meter, portable dust meter, etc., the dust meter is widely used in the Centers for Disease Control and Prevention, mines, metallurgy, power plants, chemical manufacturing, health supervision, environmental protection, environmental online monitoring etc. Dust detector, the working principle of the main light scattering method, beta ray, AC electrostatic induction principle; applicable to a variety of research institutions, meteorology, public **** health, labor health, air pollution research. Rapid detection instrument mainly has five methods: light scattering method, β-ray method and micro-weight balance method, electrostatic induction method, piezoelectric balance method.
Shenzhen Biru Blue Environmental Technology Co., Ltd. is by focusing on the field of intelligent environmental protection for many years the technical team created by the high-tech companies, the company's handheld dust detector using the principle of light scattering to the semiconductor laser as the measurement of the light source, the dust in the air for highly sensitive non-contact measurement. By the single-chip microprocessor management and control of the whole process of testing, using high-resolution large-screen high-brightness liquid crystal display, full Chinese display. Used for industrial and mining enterprises dust concentration detection and exceeding the standard alarm, with dust concentration test alarm and dust particle counting function, is the Center for Disease Control and Prevention, Labor Health Supervision, Environmental Monitoring, Industrial and Mining Enterprises and other departments of real-time rapid measurement of a new generation of intelligent measuring instruments.