Carbon dioxide laser therapy instrument of carbon dioxide laser therapy instrument

Carbon dioxide laser therapy instrument or simply light moxibustion instrument. Carbon dioxide laser, is the working substance carbon dioxide gas molecules by electric excitation produced by the laser beam, the wavelength of 10.6 microns, is a mid-infrared light.

Currently used in our country carbon dioxide laser therapy, more than 20 ~ 30W carbon dioxide laser beam scattered light, the output form of continuous emission or pulse emission, so that it passes through a small hole in the cotton plate, irradiation to the patient's acupoints, the dispersion angle of 1 ~ 10mW arc angle. In order to achieve different therapeutic effects, in recent years, many medical practitioners also use the diffusion or focusing mirror to control its power density, as moxibustion, generally using a power density of 100 to 200mW/cm carbon dioxide laser. Carbon dioxide laser therapeutic instrument using the sealing type CO2 laser, the output of invisible infrared laser, characterized by a fine beam, high energy density;

Carbon dioxide laser therapeutic instrument output of the laser through the light-guided joint arm transmission, equipped with a variety of cutterheads, suitable for a variety of purposes;

Carbon dioxide laser beam output through the focusing mirror, the focusing point of the high temperature produced by the target tissue can be vaporized, and can be used for Cutting and burning;

Carbon dioxide laser is not through the focusing mirror (direct) output, energy density is lower, can be used for coagulation of the target tissue surgery;

Carbon dioxide laser therapy instrument, such as the laser beam through the beam expanding mirror output, the laser beam is amplified by the diffusion of the irradiation of physiotherapy. 1. computer pre-set laser output power; power can be pre-set;

2. computer-controlled output modes: continuous, single, repeated pulse, ultra-pulse can be selected to meet the needs of different surgical needs;

3. red indication of the laser, pulse, continuous, aiming at the time of the surgery when there is no three kinds of working modes, so that the field of operation is more clear;

4. safety auto-detection, and the digital display of nine kinds of fault status to ensure the safety and security of the laser beam, to ensure the safety of the laser beam. Digital display of 9 kinds of fault status, to ensure safety, easy to remote maintenance;

5. With blowing function, to protect the output lens from contamination, cooling target tissue;

6. 7 joints light guide arm, flexible operation. 1. First turn on the water circulation system and check whether the water flow is smooth, the water circulation system shall not be turned on if it is faulty.

2. The patient takes a suitable position and exposes the treatment point area or site.

3. After checking whether the knob of each machine is in zero position, turn on the power, turn on the low-voltage and high-voltage switches in turn, and adjust to the optimal work flow of the laser.

4. Adjust the laser slowly, according to the treatment needs. If the laser moxibustion, use the diffuse focus lens, power density to 100 ~ 200mW/cm. thick stratum corneum parts can be slightly higher, but should not exceed 250 mW/cm. irradiation distance of 150 ~ 200cm, to local comfort and warmth is desirable, do not overheat, each treatment 10 ~ 15min. such as keloidal moxibustion, the use of focusing lens, power density of 250 ~ 477mW/cm.

5. The end of treatment, according to the opposite order to turn on the various machine button off. But be careful, do not turn off the water cycle within 15min of turning off the unit.