Imaging equipment, PACS, medical imaging quality control (revised, added)
Imaging Anatomy, CT/MR diagnostic imaging fundamentals, imaging equipment, PACS technology, medical imaging quality management
Unit Details Point Requirements
V. Human Imaging Anatomy (including planar and cross-sectional)
1. Head (1) Transverse section through the top of the cerebral hemisphere (2) Transverse section through the center of the semiovoid (3) Transverse section through the pressure of the corpus callosum (4) Transverse section through the anterior commissure (5) Transverse section through the optic chiasm (6) Transverse section through the pituitary gland Transverse section through the infraorbital fissure (7) Transverse section through the mandibular neck (8) Transverse section through the atlantoaxial medial joints (9) Transverse section through the pivotal vertebrae (10) Transverse section through the angle of the mandible ( 3. Thorax (1) transverse layer at the level of the pleural roof (2) at the level of the third thoracic vertebra (3) transverse layer at the level of the aortic arch (4) at the level of the arch of the singular vein (5) at the level of the pulmonary forks (6) at the level of the pulmonary sinus (7) at the level of the right and left inferior pulmonary veins (8) at the level of the diaphragmatic vena cava (8) at the level of the vena cava of the diaphragm (9) at the level of the diaphragmatic venous fissure (10) at the level of the pulmonary sinus and the vena cava of the diaphragm (11) at the level of the pulmonary sinus and the venous fissure of the diaphragm). >
4. Abdomen (1) Transverse fault through the second porta hepatis (2) Transverse fault through the angle of the left branch of the hepatic portal vein (3) Transverse fault through the hepatic portal (4) Transverse fault through the celiac trunk (5) Transverse fault through the superior mesenteric artery (6) Transverse fault through the hepatic portal vein at the synthesis of the hepatic portal vein (7) Transverse fault through the middle portion of the renal portal (8) Transverse fault through the lower portion of the head of the pancreas (9) Transverse fault through the horizontal part of the duodenum (10) Transverse fault through the hepatic (7) Transverse section through the superior part of the pubic symphysis (8) Transverse section through the middle part of the pubic symphysis (9) Transverse section through the inferior part of the pubic symphysis (10) Median sagittal plane (1) Transverse section through the lower part of the 3rd sacral vertebra (2) Transverse section through the upper part of the 5th sacral vertebra (3) Transverse section through the upper rim of the acetabulum (4) Transverse section through the upper part of the head of the femur (5) Transverse section through the lower part of the head of the femur (6) Transverse section through the upper part of the pubic symphysis (7) Median-sagittal plane of the female pelvis and perineum Proficiency in this area is required. Stent, chest film frame, photographic bed) mastery mastery mastery mastery
2. CR and DR equipment (1) CR equipment, the basic structure and its characteristics (2) DR equipment, the basic structure and its characteristics of the mastery mastery mastery
3. Mammography and oral photography equipment (1) mammography equipment, the basic structure and its characteristics of the basic structure of the mammography equipment (2) oral photography equipment, the basic structure and its characteristics of the equipment CT equipment (1) hardware system and its characteristics (2) software system and its characteristics (3) ancillary equipment proficiency mastery proficiency mastery understanding
5. DSA equipment (1) the basic structure and its characteristics (2) ancillary equipment mastery understanding
6. MR equipment (1) magnet system structure and its characteristics (2) gradient system structure and its characteristics (3) radiofrequency system structure and its characteristics
6. Characteristics (3) RF system structure and its characteristics (4) image processing and computer system structure and its characteristics (4) ancillary equipment structure and its characteristics Mastery Mastery Mastery Mastery Understanding
VIII, PACS technology 1. PACS development and composition (1) PACS development (2) PACS architecture and workflow (3) digital image acquisition (4) communication and network (5) image storage (6) Image Management Mastery Mastery Mastery Mastery Mastery
2. PACS Operation (1) PACS Management (2) Teleradiology (3) System Security (4) Integration with HIS/RIS (5) Routine Maintenance Understanding Understanding Understanding Understanding Understanding Understanding
3. International Standards and Criteria (1) HL7 Standard (2) DICOM Standard (3) IHE Standard Understand understand understand
4. PACS clinical applications (1) the application of the imaging department (2) the application of the clinical department proficiency mastery proficiency mastery
5. PACS progress and evaluation (1) the progress of the PACS (2) the evaluation of the application of the PACS understand understand understand
IX. image quality control 1. image quality management (1) the basic concepts, necessity and Objectives, procedures and systems (2) management methods (3) subjective, objective and comprehensive evaluation method Mastery Mastery Mastery
2. Digital radiography image quality control (1) CR image quality control (2) DR image quality control Mastery Mastery Skillfulness Mastery
3. CT image quality control (1) Factors affecting the quality of the CT image (2) image quality control contents (3 (4) image quality control methods (4) CT performance testing mastery mastery mastery mastery mastery understanding
4. DSA image quality control (1) factors affecting the quality of the DSA image (2) to improve the quality of the DSA image measures mastery
Unit Detailed Points Requirements
VII, medical imaging equipment 1. general X-ray equipment (1) equipment classification (2) basic CR and DR equipment (modification) (1) Basic structure of CR equipment and its characteristics (2) Basic structure of DR equipment and its characteristics Proficiency and mastery
3. Mammography and oral photography equipment (modification and addition) (1) the basic structure of mammography equipment and its characteristics (2) the basic structure of oral photography equipment and its characteristics to master understanding
4. CT equipment (modified) (1) hardware system and its characteristics (2) software system and its characteristics (3) accessory equipment to master understanding
5. DSA equipment (new) (1) the basic structure of the characteristics of the (2) accessory equipment to master understanding
6.
6. MR equipment (new) (1) magnet system structure and its characteristics (2) gradient system structure and its characteristics (3) RF system structure and its characteristics to master to understand to understand
VIII. PACS technology (part of the increase) 1. PACS development and composition (1) the development of the PACS (2) PACS framework and workflow (3) digital image acquisition (4) PACS clinical application (1) the application of imaging department (2) the application of the clinical department mastery
IX. image quality control (new) 1. image quality management (1) the basic concepts, the need for and objectives, procedures and systems (2) management methods (3) subjective, objective and comprehensive evaluation method mastery mastery mastery
2. CR and DR image quality control (1) CR image quality control (2) DR image quality control mastery mastery mastery
3. international standards and norms (1) DICOM standards mastery mastery
4. Quality control mastery mastery mastery
3. CT image quality control (1) factors affecting the quality of CT images (2) image quality control content (3) image quality control methods (4) CT performance testing mastery mastery mastery mastery mastery understanding