How do you use an electric grill light? What need to pay attention to

Electric grill is a physical treatment, mainly relying on electric current in the treatment of diseases in the body, electric grill lamp is divided into two kinds, one is infrared electric grill lamp, the other is electromagnetic wave electric grill lamp, infrared electric grill lamp for the revitalization of tissue cells have a very good role, but also can promote the circulation of the blood, while the electromagnetic wave electric grill lamp is a very good treatment of joint pain and so on, but the electromagnetic wave makes the harmful radiation, infrared electric grill lamp is more suitable for treatment. This kind of instrument intelligent according to the instructions to use, can not be used for a long time. The next step is to introduce the use of electric grill lamp.

Infrared electric grill lamp

1, connect the power supply: TDP therapy device power plug into 220V or (110V, 127V) socket (note that the power supply voltage should be the same as the therapeutic device design voltage), turn on the power switch, to be warmed up for 5 to 10

minutes, before radiation therapy.

2, shot site: generally in the hospital bed or lesion area of direct radiation, but also according to the motherland medicine meridian therapy principles. Generally only use a radiation head,

3, shot distance: radiation at the skin from the radiation plate 20 to 30 centimeters, the skin surface temperature is maintained at about 40 degrees

4, shot time, each radiation 30-40 minutes, 1 to 2 times a day, 7-10 days for a course of treatment. The interval between courses can be about three days. If the condition requires, continuous long-term radiation.

Precautions:

1, skin sensory disorders, scars, implantation sites, ischemic limbs should be treated with special care and frequent questioning and observation of the local reaction to prevent burns.

2, do not move the body position during treatment to avoid touching the lamps and lanterns caused by scalding, such as feeling overheated should be reported immediately.

3, treatment should avoid direct radiation eye, if necessary, with water-soaked cotton or gauze cover.

4, in the course of treatment such as fatigue and weakness, poor sleep, dizziness, etc. should stop treatment or change the treatment.

5, bedside patient treatment should be operated by personnel, should not be operated by the patient treatment. Before and after the treatment should carefully check the skin condition of the treated local area.

Infrared electric grill lamp to promote blood circulation using infrared reaction, so that the deep subcutaneous skin temperature rises, expanding the microvessels, promote blood circulation, resurrected to strengthen the blood and cellular tissue metabolism, the cells to restore youthfulness has a great deal of help, and can improve anemia.

Electromagnetic wave baking lamp use

1 access to 220v voltage, the buzzer sounded, "power" light, digital tube display 00

2 set the treatment time: press the "Time "button to set the time, press once to increase 10 minutes, up to 90 minutes, and then press and return to 00

3 set the temperature: press the "temperature" button, if the digital tube displays 10, the power of 100%, and then press the display 9, the power of 90%, and then press the power to reduce 10%, has been pressed to 5, the power is 50%, and then press to return, the digital tube shows 10, the power of 100%

4 press the "on/off" button, "work" indicator light, start counting down, the time to (display 00), "work" light, "work", "work", "work", "work", "work", "work", "work", "work", "work", "work", "work". The "work" light is off, the buzzer sounds three times, the end of this treatment

5Reset the "time", "temperature", press "on/off" and start the next treatment. Off" and start the next treatment

6 in the heating treatment, press the "on / off" button to terminate the treatment

7 if no longer continue to treat, should be disconnected from the power supply

Electromagnetic wave baking lamp precautions

1. The irradiated part of the treatment must be completely exposed, otherwise it will affect the therapeutic effect.

2. When irradiating the face, protective measures should be taken for both eyes to avoid dry eyes.

3. The therapeutic instrument should be prevented from violent vibration, moisture, pay attention to the protection of the plate surface, the irradiation head temperature is high, to avoid burns.

4. Heating resistor wire is damaged, please replace it in time.

5. In order to ensure the use of safe and prolong the life of electromagnetic wave therapy instrument, after use that is turned off the power supply, to prevent strong vibration, moisture, pay attention to the protection of the coating surface.

6. irradiated parts must be completely bare, otherwise affect the efficacy of treatment, but irradiation of the face when the patient should be wearing tinted glasses or eye masks, to protect both eyes, so as to avoid the phenomenon of dry eyeballs. If used on infants, the skin temperature is reduced.

7. The irradiation distance should not be too close, otherwise it is easy to skin burns (such as redness or blisters) or accidentally touch the paint plate; adjust the light should also be careful to prevent burns.

8. When the paint board is found to be dark red (about two years later), the surface of the board needs to be replaced.

9. Do not allow children to operate this electromagnetic wave therapy device or close to the heating lamp.

10. Before turning on the power supply, you should especially not forget to turn the power switch to the position that matches the local voltage.

11. When the electromagnetic wave therapy device does not work properly, please first check whether the fuse is damaged. If it is damaged, please use the spare part.

Through the above introduction, we must have some knowledge and understanding of the use of electric grill lamp, infrared is also a kind of electromagnetic wave, in fact, the difference between the two kinds of is not very big, the role and efficacy is also similar, are able to anti-inflammatory, pain, itching, lipid and so on. This electromagnetic wave promotes the body's blood circulation, improves the body's immunity, accelerates the healing of wounds, but also can play the effect of beauty, if encountered in the use of the process of problems, the first time should be disconnected from the power supply. Avoid problems such as burns.

Tuba Rabbit online free of charge to provide everyone with "each decoration offer, 1-4 local decoration company, 3 sets of decoration design program", as well as decoration to avoid pit strategy! Click on this link:/yezhu/zxbj-cszy.php?to8to_from=seo_zhidao_m_jiare&wb, you can get it for free Oh~