Which domestic biological safety cabinet is the best?

biobase's biosafety cabinets were the first to receive SFDA CMA certification (China Metrology Accreditation) and Class III medical device registration acceptance certificate.

National standards Strictly in accordance with national standards, higher than the American Standard NSF49, EN12469.

SFDAIII registration The first to obtain SFDA product registration inspection certificate.

ISO9001 The production base has passed ISO9001 quality system certification

ISO14001 The production base has passed ISO14001 environmental management system certification

Negative pressure Vertical laminar flow, three negative pressure

Wind speed control With the air supply and exhaust air speed probe,

Can be on-line testing of the wind speed. Dynamic display, real-time control

Air pressure control When the air pressure changes by 50%, the air volume changes by no more than 10%

Filtration efficiency ULPA ultra-high-efficiency filters 0.1-0.2umDOP

Diameter particles filtration efficiency of more than 99.999%

Filter protection Double-sided protection

Replacement of filters The inlet and outlet filters can be replaced in the front

Filter replacement Filter can be replaced in the front

Working chamber The working table is 304 stainless steel

, R20 seamless rounded structure new appearance Patent No.: 200430047816.7

Panel display High brightness VFD display Patent No.: 200420053105.3

Reservation timer The switching time can be set, and the on/off function is available. Switching function

Patent No.: 200420053409.1

Remote control Equipped with a special remote control, which can be controlled through two layers of glass

Patent No.: 200420053408.7

Biological testing Each product has passed the testing of the Institute of Microbiological Safety of the National Academy of Military Sciences

Microbiological Safety Institute.

Environmental testing The products have passed the toughest environmental tests in the environmental laboratory with the temperature of -40℃-50℃ and

humidity of 5%-100%.

Service network With a complete after-sales service system, the network throughout the country

One, high-brightness color VFD display

VACUUM FLUORESCENT DISPLAY (VACUUM FLUORESCENT DISPLAY) from the development of vacuum tubes from the display, by the cathode of the emitted electrons (direct thermal, collectively referred to as the filament), the acceleration of the control of the It consists of a cathode that emits electrons (direct heat type, collectively known as filament), a gate that accelerates and controls the flow of electrons, an anode with electrodes and phosphors printed on a glass substrate, and a grid and glass cover. It is a self-luminous display device that utilizes electrons to impinge on the phosphor, causing the phosphor to emit light.

Compared with LED, LCD, because it can do multi-color display, high brightness, not affected by the surrounding environment, even at night, but also emit the same bright light.

The life span of VFD is more than 30,000 hours of continuous working life, that is, it can continue to work for more than ten years, which is almost twice as long as the life span of LCD and LED.

The company's VFD adopts dynamic display technology, which makes the brightness of the screen more uniform and consistent, and dynamically reflects the work of the instrumentation, such as the effective working condition of the filter. It gives the user an intuitive feeling.

VFD display content:

1, Lighting (LIGHT)

2, Sockets (SOCKET)

3, Fans (WM)

4, Sterilizing (KG)

5, air supply, exhaust air pressure (EW, DW)

6, air supply, exhaust air filters, the efficiency of the EW, DW)

7, foot switch (FOOT SWITCH)

8, reservation, timing time setting (SUB INSTIME)

9, the control of the glass door and the status of the (GD)

Two, the remote control

Near-range operation is very inconvenient for the user, bioclean safety cabinets are equipped with a special remote control, which is small in size and 7 mm thick. The remote control is small in size, 7mm thick and light in weight, only 18 grams, the user can carry the operation. Avoid direct contact between the user and the safety cabinet. Prevent cross-infection.

The remote control using Japan NEC remote control chip, with good anti-interference performance, remote control distance, control precision and other characteristics.

Three, electric glass door control

The front glass door and window for electric control, with the remote control can be controlled at will, without the need for direct contact between the user and the glass door and window. Glass door control motor for the Japanese Mitsubishi company special reversible speed motor, the motor has accurate speed regulation, starting torque, smooth rotation characteristics.

Four, the application of appointment timing

Biological clean safety cabinet must be closed before the use of the glass door and window sterilization for more than 30 minutes, and the staff will have to wait for 30 minutes every day to work, based on the above considerations, the safety cabinet to increase the unique appointment function, the day before the end of the day, set up the power-on time and power on the function, set the time range of 0-99 hours. -99 hours. Before the arrival of the staff, the safety cabinet has been fully automatic implementation of the completion of the preset functions, in line with the requirements of the working conditions, greatly improving the efficiency of the staff.

Nationwide with maintenance service stations.

From the front of the safety cabinet to replace and repair filters and fans, maintenance is more convenient