Medical examination center as the characteristics of the public **** place, its interior design and decoration requirements are not the same as other buildings, decoration design specifications need to decorate the enterprise in strict accordance with the requirements of the design, the decoration materials are also different from the ordinary decoration materials, the following is a detailed analysis of the standardization of the decoration design of the physical examination center.
One, the basic concept and the general idea
1. Physical examination center is also a place of consumption and property
According to the principle of market economy, people on the physical examination center is also a consumer behavior, the physical examination of the consumption of high enough to remind people to carry out enough physical exercise. Physical examination centers, like other buildings, are also a kind of property and should also be operated according to the laws of property management.
2. Cultural design and CI design
Following the principle of the generality of the physical examination center, highlighting its specificity. Reflect simplicity, efficiency, humanity, environmental protection.3. Barrier-free design
Toilet seats for the disabled should be set up independently, and the dedicated space is the largest. Stairs should be equipped with double conductor handrail for the convenience of adults and children. Stairs should have starting and stopping instructions for the blind. Elevator door and car box need to consider the wheelchair, stretcher car impact protection.4. Lighting
For consumers, lighting should not be too bright, nor too dull. Should avoid lamps _ light. Light color is best to choose a good color rendering and slightly warmer. 5. water supply and sewage
From the system selection, piping arrangement, pipes and fittings to consider the epidemic prevention requirements, to ensure water quality, to prevent cross-infection. Adoption of non-manual switch. Sewage is classified for collection, treatment and reuse.6. Management Intelligent System
The standard version includes modules of consultation, reservation, billing, examination, inquiry, costing, filing and personnel management, and nurses' station management. Requirements placed in a reasonable location; facilities _ color and coordination with the surrounding environment; can be hidden as much as possible concealed.7. Building Control Intelligent
Including air-conditioning, computer stations, local area networks, multimedia, the general control room, elevators, five gas, call to the intercom, integrated wiring, security monitoring, fire protection, communications, cable television, garbage and water treatment systems. Requirements for decorative style should be coordinated with the overall space; decorative materials and the original facility materials are coordinated, no obvious sense of modification; such as the external exposure of the facility part of the modeling, _ color, texture and other aspects of the overall environment is a big difference, it is really necessary to replace but can not be hidden, should be adjusted with the supplier before the installation, in order to avoid the loss of all; the equipment outside the decorative surface of the exposure of the cross to be with the decorative finishes modeling, line formation Rhythm, while ensuring that the function of the equipment is not affected.8. Professional logo design
The text, pattern, color logo should be eye-catching, clear, clear. Different sections can use different colors. Color should be light and harmonious. Pay attention to the Chinese and foreign language, style, location, _ color, shape, texture, decoration and decoration. Divided into three major types.
Outdoor category: First, the whole area of the medical examination center of each single building guide signs and building signs; second, the road guide; third, the medical examination center service facilities guide.
Floor category: First, the indoor functional general plan and the functional plan of each floor; second, the signs required by the national norms (fire escapes, entrances and exits, etc.). Section unit category: First, the physical examination center door, window sign; Second, the public **** service facilities signage; Third, the special markings required by the industry.
Two, different functional space considerations
1. parking lot
The ground parking lot should have a special waiting space for cabs and access to the flow line. 2. consulting, booking hall
It is the crossroads of a variety of medical examination centers, the most intensive public places. Male guests, female guests need to be divided into streams, and distinguish between traffic and detention space - to facilitate the organization and channeling of the flow of people. Natural lighting and ventilation, and skylight form.
Consultation, reservation, and payment counters, 750mm in length, change standing service to seated service. Set up a large screen to display a variety of relevant information. Business desk should arrange a sufficient number of rows of chairs, rows of chairs from hard to soft, rows of chairs to sofa change.
3. Corridor
Marquee rest chairs are set up at the entrance of each department, which are suitable for fixed type and soft package (removable and washable). And equipped with garbage cans.
3. Public **** bathroom
Under the premise of solving the problem of visual interference, advocate doorless bathroom. The establishment of a dedicated cleaning room. Urinal, should avoid step-up type. Toilet, sitting type is more comfortable, but to solve the one-time self-padded paper (recommended the use of automatic pad changer); squatting type, to make the toilet and the ground in the same two sides, set up infrared sensor flushing. Install handrails, hooks and small shelves on the toilet partitions, and the partitions should have a certain height. Faucet, urinal and toilet should be sensor type. The hand dryer should be suitable for wiping hand paper. Should be set up in the visual conspicuous place in what circumstances should wash their hands sign.
Walls can be finished with glossy blocks to minimize wide seams. It is advisable to use specialized caulking. Can also use the back of the baking paint tempered glass. The floor can be used stone or tile, 500 × 500mm is preferred, large blocks should not be drained. Partition can be used MAX board, site assembly.
4. CT, X-ray room
This type of space is important to meet the requirements of anti-radiation, based on the equipment manufacturers to provide the lead equivalent of the maintenance structure of the lead plate selection of the lead plate will be composite in the back of the aluminum plate. All walls except the door and lead off the window, are available to talk about the color of elegant aluminum plate overhead installation, pay attention to the fixed screw holes lead to protective loopholes, preferably for the paste type. Lead plate door should be used to decorate the surface of the adhesive plate, vertical direction is generally no anti-radiation requirements, can be used in aluminum ceiling.
5. Inspection room
The inspection room independent room, reasonable process, each inspection room net area of not less than 8_. When the examination room is set up for more than one person to use the net distance between the examination bed is not less than 2m, must be set up soft partition. The ophthalmology department should set up another special dark room. Color tone warm, bright, ceiling is not easy to have a variety of molding, more mineral wool board or paper-faced gypsum board. According to the needs of the department set up clean pool. Window opening for the inverted opening is appropriate. In order to meet the ventilation, safety and protection, easy to clean three needs.
8. Medical furniture and environmentally friendly decorative materials
Seat height should be 90 ~ 420mm, furniture materials should be considered durability, pollution resistance, chemical corrosion resistance and other environmental characteristics, such as the Dutch Trespa. Decorative materials such as environmentally friendly latex paint, ground aluminum anti-static flooring, imported rubber flooring. Section - rubber flooring. Toilet, locker room, machine room, archive room, storage room, smoking room, water boiler room, fire ladder and channel - floor tiles. Lobby, corridor - imitation wood grain (tile, stone) plastic flooring. Administrative office - office block carpet. Scientific research, inspection - anti-static flooring, anti-corrosion floor tiles. Ceiling: appointment hall - modeling gypsum board; corridor - gypsum board (aluminum, mineral wool board); section - public **** bathroom - aluminum button board;. Walls - sterilized colored latex paint; bathroom walls: tiles all wall sun corners should be installed with anti-collision corner guards. Smoking room wall - tempered glass (clear glass)
Three, professional requirements
1. Professional requirements
No dust, no accumulation of dust, corrosion-resistant, moisture-resistant, mildew-resistant, fire-resistant, easy to clean. The color should be mild, light, can be light green, light yellow. Green and red blood complementary colors, can reduce eye fatigue of health care workers, and medical examiners have a calming effect on the psyche. Yellow has a balanced emotional downturn, to avoid convergence with the green wall.
Electrical design, purification and air-conditioning design, and terminal design should be in accordance with the requirements of specialization of interior design and decoration construction.3. Six-sided requirements
The ground. Should be flat, using environmental protection, antibacterial, wear-resistant, non-slip, corrosion-resistant, easy to clean, easy to dust and non-cracking decorative materials, pay attention to the rubber flooring or artificial stone flooring, along with the ground jointed into a shadowy corner treatment. Wall. It is appropriate to use light steel keel gypsum board partition wall.
Walls can be tilted inward by 3 degrees, which not only reduces the accumulation of dust, but also makes the angle of light reflection conducive to the operation of health care workers. Skirting board should be recessed into the wall 1cm, and become one with the ground, the corner radius is 40mm rounded.
Ceiling. Need to layout, installation of high-efficiency filtration air supply, lighting fixtures, smoke detectors and fire extinguishers, etc., a variety of pipelines should be hidden in the ceiling. Also available aluminum, mineral wool board ceiling.
Doors and windows. Should be used to prevent dust sealing sound insulation effect of the hollow double window, can choose stainless steel or plastic steel special window. The door should adopt automatic induction type electric color steel plate sliding door with time delay.