Water supply equipment pump power, head, pipe diameter, flow rate how to calculate, there is a formula?

There is a formula.

1, the flow rate according to the user's water point of each household, according to the water equivalent statistics;

2, head according to the least use of the water point height plus the local loss, the extended range loss and rich head can be obtained;

3, according to the flow rate head, according to the pump you want to choose, you can choose the right model, you can know the pump power;

4, pipe diameter According to the economic flow rate can be obtained; the formula is:

Pipe diameter: DN = [4Q / (V × 3.14 × 3600)] 0.5 × 1000, where: Q: for the pump flow rate m3 / h, V: water flow rate m / s, DN: nominal diameter of the pipeline mm

5, the flow rate of the water is generally in accordance with the economic flow rate calculations:

Diameter of the pipe (mm) DN <250250≤DN≤10001000≤DN≤1600DN≥1600

Inlet pipe flow rate (m/s) 1.0-1.2; 1.2-1.6; 1.5-2.0; 1.5-2.0;

Outlet pipe flow rate (m/s) 1.5-2.0; 2.0-2.5; 2.0-2.5; 2.0-3.0. 3.0.

Expanded Information:

Water supply equipment classified as:

1, fire-fighting water supply equipment: for fire-fighting purposes of water supply equipment.

2, living water supply equipment: water supply equipment for living purposes.

3, production water supply equipment: water supply equipment for production purposes.

4, sewage treatment water supply equipment: water supply equipment for sewage treatment purposes.

5, other: equipment for the production of water supply equipment for the production of water for the dual-mode industrial and mining enterprises.

Baidu Encyclopedia - water supply equipment

Baidu Encyclopedia - water pumps