What are the sterilization and purification units in the operating room

Ordinary operating room with alcohol, laminar flow operating room mainly rely on air purification unit in the ozone generator or dynamic disinfection machine. After each surgery, do a good job of cleaning, open the ozone generator or dynamic disinfection machine, about 40 minutes, that is, disinfection is complete. Anhui people and purification for you to introduce the operating room disinfection isolation system.

Operating room disinfection and isolation system

1, carefully implement the disinfection and isolation system. Enter the operating room according to the prescribed route. Change slippers before entering the dressing room, then change clothes, wear masks and hats.

2, strict division of three zones: contaminated area, clean area, sterile area.

3, the operating room items placed neatly, clean and dust-free, no blood, personal belongings and books and newspapers are not allowed to bring into the operating room, is strictly prohibited in the operating room to do dressing packing.

4, carefully implement the sterilization specifications, packaged according to the specifications. Under the exhaust pressure sterilization maximum package volume shall not exceed 30cm × 30cm × 25cm; a variety of dressing packages, instrument packages are placed on the sterilization instruction card, 3M tape outside the package, chemical monitoring (tape length as required). Dressing packages not more than 5Kg; metal packages not more than 7Kg.

5, sterilized packages should be stored in the sterile goods cabinet, the validity period of 1 week, the expiration date should be re-sterilized, cloth dressings wrapped skin without mutilated and broken and sewing, not wet.

6, medical personnel should check the integrity of the packaging and sterilization date when using sterile goods and instruments. Sterile packages opened although not used, considered contaminated, must be re-sterilized.7, the surgical process, the staff strictly aseptic operation, intravenous infusion to do one person, one needle, one tube, one belt. Anesthesia items should be sterilized once used, and disposable medical devices and instruments should not be reused.

8, strict implementation of instrument decontamination process, surgical instruments and items should be rinsed first, then disinfection and sterilization, there are joints, crevices, grooves of the instruments, should try to open or dismantle, to ensure that the cleanliness of the instruments to ensure that the cleaning effect and the quality of sterilization; cleaning, disinfection and sterilization of luminal scopes to keep a good record.

9, the operating room daily timed ultraviolet air disinfection, disinfection time of 45 minutes, twice a day, weekly ultraviolet lamps with 95% alcohol cotton ball wipe once a month on the ultraviolet lamp monitoring.

10, daily monitoring of the concentration of disinfectant in use, and can master the preparation method.

11, operating room operating room strict hygiene, sterilization system. Daily wet wipe cleaning and disinfection before and after surgery, wall surface wiping height of 2-2, 5m, without cleaning and disinfection of the operating room shall not be used continuously. Thorough sanitation cleaning 1 time a week, the use of brooms, mops, strictly in accordance with the distinction between the districts.

12, the operating room set up isolation operating room, dedicated to emergency, infectious diseases and infected patients surgery; infectious diseases or isolation of the patient's surgical notification form, it should be noted that the "emergency", "some kind of infection" or "some kind of laboratory results abnormal" situation; strict isolation management, post-operative instruments and articles in accordance with the decontamination process, and then autoclave sterilization.

13. Post-operative dirty dressings are placed at fixed points and handled according to regulations. Surgical waste is placed in a yellow plastic bag and closed for transportation to the designated place. Medical personnel removed surgical gowns, gloves, masks and other items should be placed in the designated location before leaving the operating room.

14, according to the contamination and infection of surgical patients and surgical parts of the reasonable arrangement of the operating room; on the successive stages of surgery should be done between the disinfection of the successive stages, to ensure that the disinfection time and disinfection effect.

15, strict implementation of sterilization effect monitoring standards, sterilization pot sterilization kit inside and outside the monitoring of chemical indicators.

19, staff suffering from upper respiratory tract infections or other infectious diseases should be restricted from entering the operating room work.

The above by the people and purification for your answer, hope to adopt!