The management regulations for oxygen cylinders are as follows: 1. In order to ensure the rescue and operation of critically ill patients, the hospital should ensure 24-hour oxygen supply.
2, oxygen cylinders should be transported by designated personnel, and check the storage of oxygen cylinders at any time, to ensure emergency at night.
3, oxygen pressure gauge and other ancillary equipment, the equipment department is responsible for the maintenance.
4. In order to ensure safety, the oxygen cylinder storage door should be locked on the door, and more attention should be paid to the temperature of the warehouse in summer to avoid fire and explosion accidents.
Medical oxygen management system. Provisions on the use and management of medical oxygen:
1. According to the Drug Administration Law of People's Republic of China (PRC) and its related regulations, medical oxygen belongs to emergency drugs and is managed by pharmacy department.
2. Medical oxygen cylinders belong to equipment and are the fixed assets of our hospital.
The pharmacy department is responsible for the safety of medical oxygen cylinders in our hospital.
3. The quality standard of medical oxygen conforms to People's Republic of China (PRC) Pharmacopoeia and related regulations, and the filling pressure is 12.5kpa/㎡.
In the process of clinical use, if quality problems are found, they should be reported to the pharmacy department for proper handling and resolution.
4, the oxygen department according to the situation to give a certain number of oxygen cylinder base, every Monday and Friday for pharmacy support day, the head nurse of each department, department director to make a good plan for a week with oxygen, with empty oxygen cylinders to the pharmacy in exchange for medical oxygen cylinders.
5, the relevant departments responsible for the medical oxygen safety of undergraduate course room.
The pharmacy department will regularly or irregularly clean the steel oxygen cylinders of relevant departments, and if it is found to be lost, the department where it belongs will be responsible for compensation.
The unit price of each oxygen cylinder is one thousand yuan (1000.00 yuan/bottle).
Two, medical oxygen safety management regulations:
1, this product has strong combustion-supporting gas.
It is strictly forbidden to contact inflammable and explosive articles such as grease, fireworks, etc.
2. When storing or storing this product, it must be far away from fire sources, and there are safety fire-fighting facilities, such as fire extinguishers and sand buckets.
3, this product storage, use, handling, storage, it is forbidden to impact, in order to avoid explosion.
Oxygen is essential for hospitals, and it is also a burning dangerous goods. In order to effectively strengthen the management of safe use of oxygen, this system is formulated.
1, where oxygen cylinders are stored, fireworks, flammability and explosion are strictly prohibited, and dangerous goods such as oil must be managed by special personnel, and fire and explosion prevention work should be done well, and fire equipment should be equipped.
2, oxygen bottle management, handling personnel strictly implement safety operation procedures and safety system.
Avoid collision when handling oxygen cylinders. Users should pay attention to safety and are not allowed to smoke.
Oxygen cylinder valves and pipeline switches must be checked and closed frequently, and air leakage is not allowed.
Non-staff shall not use it.
3, strictly implement the relevant provisions of the superior, oxygen cylinders are regularly pressure tested and scrapped, with obvious signs, complete accounting, and do a good job of annual inspection.
4, oxygen and equipment maintenance and transportation, etc. The General Affairs Department shall be responsible for the oxygen cylinders collected by the General Affairs Department, and the oxygen cylinders shall be closed in time after use based on the principle that whoever uses them is responsible. Smoking and naked flame are strictly prohibited to ensure safe use.
Oxygen cylinder management system 1. According to the Drug Administration Law of People's Republic of China (PRC), medical oxygen belongs to emergency drugs, and its quality standard should comply with the relevant provisions of People's Republic of China (PRC) Pharmacopoeia.
2. The person responsible for the safe use of oxygen cylinders is the medical staff who use oxygen cylinders, and the person responsible for daily maintenance is the head of the outpatient department.
3. Oxygen cylinders are pressure vessels. In the process of handling, transportation, storage and use, attention should be paid to safe operation and gentle action. It is forbidden to hit and knock to protect the auxiliary facilities such as oxygen cylinder head, pressure reducing valve and pressure gauge from external force.
4. Oxygen cylinders must be placed away from fire sources and high temperature environment, and it is forbidden to contact with grease substances. It is forbidden to place inflammable and explosive articles near oxygen cylinders, and it is forbidden to smoke indoors with oxygen cylinders. At the same time, it should be equipped with safety fire control facilities.
5. Industrial oxygen shall not be used instead of medical oxygen. Medical oxygen should be filled in regular gas stations with corresponding qualifications, and oxygen cylinders should be filled with new oxygen. Medical oxygen certificate? , and indicate the production date and validity period.
6, more than the expiration date of medical oxygen shall not be used for clinical, and should be added in time.
7, when the oxygen pressure in the bottle is less than 10 kg/cm, should be refilled, it is forbidden to completely use up the oxygen in the bottle.
8, humidifier water should be replaced once a week, distilled water or pure water should be used, and the liquid level is between the highest and lowest water levels indicated by the humidifier bottle.
9. Oxygen straws or masks should be used by one person, and should be cleaned and disinfected in time after use.