Water-cooled air conditioners are mainly improved products for factories, supermarkets, and the garment industry where the density of workers is relatively high. Than the existing air conditioning power saving eighty percent, on the current rise in electricity costs, water-cooled air conditioning is everyone's first choice. Energy-saving environmental protection air conditioning many years ago in Austria, the United States and the Middle East and other regions in large numbers, only in recent years began to enter the Chinese principle of its work for the water molecules with the liquid state into a gaseous state need to absorb a considerable amount of energy if the energy is obtained from the air, and the result is to make the air in the reduction of sensible heat to make the air temperature lower. The environmental protection chiller is suitable for open-type use can be directly transported to the natural wind and transported to the cooling of the cold air, outdoor fresh air filtered by the environmental protection chiller
Cooling and increase the oxygen content and other multiple effects, especially for heat dissipation or crowd-intensive places.
The core component of the energy-saving environmental protection air conditioning is a direct evaporative heat exchanger (wet curtain) and its inter-heat transfer effect is close to the surface area
100 times, can be achieved below the outside world 5 ℃ ~ 12 ℃ of the cooling effect, and the traditional central air-conditioning equivalent.
Save 80% of the electricity consumption of the equipment. And has the advantages of easy installation and maintenance, very low operating costs, durable and so on.
Wet curtain chiller (environmental protection air conditioning) is composed of a large surface area of special paper corrugated honeycomb wet curtain, high-efficiency energy-saving fan, water circulation system, float valve replenishment device, casing and electrical components, etc., and its central part of the high-tech products used in Sweden CELDRK? The cooling principle is: when the fan is running the chiller cavity produces negative pressure, so that the air outside the machine into the porous wet wet curtain surface into the cavity, the wet curtain on the water in the adiabatic state of evaporation, take away a large amount of latent heat, forcing the dry bulb temperature of the air over the curtain down to close to the wet bulb temperature of the air outside the machine, that is, the dry bulb temperature of the chiller outlet than the dry bulb outdoor temperature is lower than the dry bulb temperature of 5-12 ° C (dry and hot areas up to 15 ° C) The more dry heat, the greater the temperature difference, the more dry heat, the greater the temperature difference. The dryer and hotter the air, the greater the temperature difference, the better the cooling effect. As the air is always introduced into the room from outdoor, so it can maintain the freshness of indoor air; at the same time, as the machine utilizes the principle of evaporation cooling. Therefore, with cooling and humidification double function (relative temperature up to 75% or so), in the textile, knitting and other workshop use, not only can improve the cooling and humidification conditions, but also purify the air, reduce the needle spinning process of needle consumption and filament breakage rate, improve the quality of needle textile products Picture:
/upfile/20050811153801656.jpg