Question 2: What are the code names of water quality testing items? Suspended substance SS
Chemical requirement COD
Biochemical oxygen demand BOD5
Anionic surfactant LAS
Dissolved total solid TDS
dissolved oxygen
Nitrate nitrogen NO3-N
Nitrite nitrogen NO2-
Ammonia nitrogen NH3-N
Hexavalent chromium Cr6+ ion
Total nitrogen TN
Total phosphorus TP
Question 3: What items do water quality testing generally do? Hello!
Suggested test items are as follows:
HCT rainbow detection, pour love to answer for you!
Question 4: What are the testing items of lake water quality? H-BD5 universal water quality tester is an expert analysis system of intelligent system with built-in single chip microcomputer. The system design has the most advanced hardware and professional analysis software system. All data can be saved when power is cut off. Each instrument provides the most professional analysis/testing technology and the most professional curing method. Have the ability of field bus support and RS232/485 communication interface. Other advanced instrument accessories of Big Dipper can be selected, such as instrument modem. You can get technical support from Big Dipper engineers through telephone dialing or the Internet. You can refresh the program. BD5 tester enables most instruments to provide full range test, which saves the trouble of range selection.
The hand-held sensor of Big Dipper is ingenious in design, which can be used as a general instrument, can be directly used for grinding bottles, and can also be connected to the pipeline through pipe threads for temporary continuous detection.
H-BD5 universal analyzer can be used for any electrochemical electrode sensor (other products can also be used) or other sensors of the Big Dipper. The system is equipped with multiple calibration tables. A total of * * * set 45 channels (to be added in the future). It has 100 data storage functions. The main channel can be set to record the storage mode of the reaction process. When using multiple single probes, there is no need to worry about the data loss of the calibration table. Just change the probe and enter the calibration number with the keyboard.
Portable intelligent water quality analyzer, environmental pollution water quality analysis and measurement instrument, portable water quality analysis equipment, water quality detection instrument, water quality analyzer, portable water quality tester, intelligent water quality monitor, salinity meter,
H-BD6-WQA Multifunctional Water Quality Analyzer
H-BD6-WQA48 18 Portable Multifunctional Photometer Water Quality Emergency Detector [Introduction] [Selection Data] [Application]
Without reagents and treatment, it can directly test the total amount of chemical pollutants TDC/COD tester /COD rapid tester, biological content /BOD, total organic matter/oil TDO/ oil infrared oil analyzer, suspended matter or turbidity SS/Turb, pollution index/chroma WAI/Color, and water quality comprehensive toxicity analyzer.
Provides three bands of commonly used colorimeters. Almost all common pollutants can be analyzed by combining standard methods of water quality analysis with necessary reagents.
Question 5: What is the project of domestic sewage quality testing? Runde Purification has learned that environmental water quality testing includes: surface water, groundwater, drinking water, landscape water, reclaimed water and wastewater testing.
The main pollutant monitoring items of domestic sewage monitoring include: chemical oxygen demand, biochemical oxygen demand, suspended matter, ammonia nitrogen, total phosphorus, total nitrogen, anionic surfactant, total bacteria, coliform bacteria and so on. Please refer to the local standards or industry standards of different places and industries.
Chemical oxygen demand: detection method standard: GB11914-89;
Biochemical oxygen demand: detection method standard: HJ 505-2009;;
Suspended solids: detection method standard: GB/T11901-89;
Ammonia nitrogen: detection method standard: HJ 537-2009;;
Total phosphorus: detection method standard: GB 711893-89;
Total nitrogen: test method standard: HJ 636-2012;
Anionic surfactant: test method standard: GB 7494-87;;
Total number of bacteria (collaboration), detection method standard: Monitoring Methods of Water and Wastewater, 4th edition, Chapter 2, Chapter 4 and Chapter 5;
Coliform group (cooperative group), detection method standard: Monitoring Methods for Water and Wastewater, 4th edition, Chapter 5, Chapter 2 and Chapter 5.
Question 6: What data should be tested for water quality testing? Detection of domestic sewage quality.
Environmental water quality testing includes: surface water, groundwater, drinking water, landscape water, reclaimed water and wastewater testing.
The main pollutant monitoring items of domestic sewage monitoring include: chemical oxygen demand, biochemical oxygen demand, suspended matter, ammonia nitrogen, total phosphorus, total nitrogen, anionic surfactant, total bacteria, coliform bacteria and so on.
Chemical oxygen demand: detection method standard: GB11914-89;
Biochemical oxygen demand: detection method standard: HJ 505-2009;; ;
Suspended solids: detection method standard: GB/T11901-89;
Ammonia nitrogen: detection method standard: HJ 537-2009;; ;
Total phosphorus: detection method standard: GB 711893-89;
Total nitrogen: test method standard: HJ 636-2012; +02;
Anionic surfactant: test method standard: GB 7494-87;;
Total number of bacteria (collaboration), detection method standard: Monitoring Methods of Water and Wastewater, 4th edition, Chapter 2, Chapter 4 and Chapter 5;
Coliform group (cooperative group), detection method standard: Monitoring Methods for Water and Wastewater, 4th edition, Chapter 5, Chapter 2 and Chapter 5.
The above is answered by Beijing Dayuan Environmental Testing Technology Research Center. Thank you for your adoption. . .
Question 7: What are the methods of water quality testing? H-BD5 universal water quality tester is an expert analysis system of intelligent system with built-in single chip microcomputer. The system design has the most advanced hardware and professional analysis software system. All data can be saved when power is cut off. Each instrument provides the most professional analysis/testing technology and the most professional curing method. Have the ability of field bus support and RS232/485 communication interface. Other advanced instrument accessories of Big Dipper can be selected, such as instrument modem. You can get technical support from Big Dipper engineers through telephone dialing or the Internet. You can refresh the program. BD5 tester enables most instruments to provide full range test, which saves the trouble of range selection.
The hand-held sensor of Big Dipper is ingenious in design, which can be used as a general instrument, can be directly used for grinding bottles, and can also be connected to the pipeline through pipe threads for temporary continuous detection.
H-BD5 universal analyzer can be used for any electrochemical electrode sensor (other products can also be used) or other sensors of the Big Dipper. The system is equipped with multiple calibration tables. A total of * * * set 45 channels (to be added in the future). It has 100 data storage functions. The main channel can be set to record the storage mode of the reaction process. When using multiple single probes, there is no need to worry about the data loss of the calibration table. Just change the probe and enter the calibration number with the keyboard.
Portable intelligent water quality analyzer, environmental pollution water quality analysis and measurement instrument, portable water quality analysis equipment, water quality detection instrument, water quality analyzer, portable water quality tester, intelligent water quality monitor, salinity meter,
H-BD6-WQA Multifunctional Water Quality Analyzer
H-BD6-WQA48 18 Portable Multifunctional Photometer Water Quality Emergency Detector [Introduction] [Selection Data] [Application]
Without reagents and treatment, it can directly test the total amount of chemical pollutants TDC/COD tester /COD rapid tester, biological content /BOD, total organic matter/oil TDO/ oil infrared oil analyzer, suspended matter or turbidity SS/Turb, pollution index/chroma WAI/Color, and water quality comprehensive toxicity analyzer.
Provides three bands of commonly used colorimeters. Almost all common pollutants can be analyzed by combining standard methods of water quality analysis with necessary reagents.
Question 8: What are the contents of the industrial wastewater testing project? Abstract: Industrial wastewater includes production wastewater and production sewage, which refers to wastewater and waste liquid produced in industrial production, including industrial raw materials, intermediate products, by-products and pollutants produced in the production process. Water discharged during production.
Harm of industrial wastewater
The increasingly serious water pollution has posed a great threat to human survival and safety. Heavy industry wastewater, which has become the sustainable development of human health, economy and society, includes production wastewater and production sewage, which refers to wastewater and waste liquid produced in industrial production, including industrial raw materials, intermediate products, by-products and pollutants produced in the production process. Water discharged during production.
Harm of industrial wastewater
The increasingly serious water pollution poses a great threat to the survival and safety of human beings and becomes the main obstacle to the sustainable development of human health, economy and society. According to the survey of international authoritative organizations, in developing countries, 80% of various diseases are spread by drinking unsanitary water, which causes at least 20 million deaths worldwide every year. Therefore, industrial water pollution is called the world's number one killer.
(1) Whether the discharge exceeds the standard. Mainly check whether the COD in supervisory monitoring results, online monitoring results and factory effluent monitoring results exceeds the standard, and also pay attention to other indicators, such as total phosphorus and ammonia nitrogen. If it exceeds the standard, there must be corresponding detection documents; If the monitoring results exceed the standard by more than 30%, we should carefully find out the reasons and correct them.
(2) Whether the monitoring frequency meets the requirements. On-line monitoring device should operate normally. Supervision and monitoring should be at least once every quarter. The factory basically has to ensure that it is monitored once a day.
(3) Check the consistency of supervisory monitoring data with online and factory monitoring data on the day of sampling.
(4) Accounting removal efficiency. The closer the influent concentration is to the design concentration, the higher the removal rate of sewage treatment facilities.
(5) influent concentration. The abnormal increase or decrease and excessive fluctuation of influent concentration should be paid attention to and explained.