Address: Dongsi South Street 164, Dongcheng District
Introduction: Dongsi IDC computer room is located in the northeast of the intersection of Dongsi South Street and Jinbao Street. It is the most prosperous business district in Beijing. Close to Chang 'an Avenue, with its superior geographical position, it provides customers with fast and high-quality services. It is a leading data center in China with world-class standards, with high-speed optical fiber lines, perfect network environment and professional network management technology. With world-class facilities, rich telecommunication resources, operating experience and advanced network equipment, it can provide you with high-quality IT services and save you time and cost. ?
Dongsi IDC room covers an area of about 700 square meters and is located in the main building. Provide customers with open rack hosting service, with double connection of carrier-grade high-end routers, and the single link load does not exceed 50%. The network access equipment is connected to the network core node through dual-machine hot standby. Two lines of commercial power are connected to the 2+ 1 standby dual-bus UPS system, and the diesel generator is standby. The bearing capacity of the machine room floor is more than 600kg/㎡, the seismic intensity is more than 8 degrees, the height under the beam is more than 4.5m, the ambient temperature of the machine room is 22 2℃, and the humidity is 30 ~ 70%. 7x24 network technical support and fire safety service.
Transportation: Dengshikou Station of Metro Line 5.
The computer room of Dongsi Telephone Office was newly opened in June 2008. Located in the city center, with an area of about 700 square meters and about 264 shelves. At present, the total export bandwidth is 20G, the network access equipment adopts dual-machine backup, and the uplink adopts double return uplink mode. The computer room has a professional operation and maintenance team with strong technical force.
Computer room parameters
IDC computer room area? 700 square meters? Total access bandwidth 20G?
How many racks is the computer room designed? How many racks are there in the computer room? 264?
What is the rack size of the computer room? 600mm*900mm*2000mm? What are the opening hours of the computer room? In 2008?
What is the ip number of a single cabinet? Hardware firewalls and indicators? Optional? Dynamic standard? A commercial force
Main and standby diesel generator sets?
Dual redundant (1+ 1)UPS power supply?
What kind of value-added services are carried out? Network (host) monitoring, remote management (KVM), host leasing, traffic monitoring and analysis, network security monitoring, network security equipment leasing (firewall, IDS, IDP, UTM, etc. ), network security assessment and reinforcement, emergency response, website protection, security inspection, on-site duty, etc.
Total accumulated investment? Invest this year? Total investment to be invested?
Feature description
Beijing Unicom data center currently has 22 large professional computer rooms with international standards, which are distributed in all urban areas of Beijing, making it convenient for customers to choose nearby;
High reliability, providing 7×24-hour all-weather operator-level operation service, professional and technical personnel are responsible for maintenance, stable network and higher security performance;
Good flexibility, can provide customized services according to customer needs.
Detailed introduction
1、? Computer room bandwidth
Cisco high-performance routers and switches with 8G bandwidth and dual-star redundant topology provide fast and reliable support for various services? .
2、? electric power system
Two-way first-class commercial power, super-large capacity main and standby diesel generator sets, redundant UPS standby power supply. UPS spare battery capacity is not less than 60 minutes.
3. Air conditioning system
Temperature 2 1-25
4. Security system
Monitoring system 7 days ×24 hours omni-directional computer room monitoring video; The access control system double verifies the identity of visitors through fingerprints and IC cards to prevent any irrelevant personnel from entering.
5. Fire control system
High-sensitivity laser active early smoke detection and alarm system ensures that fire hazards are found at the first time, and gas fire extinguishing system can put out the fire without power failure.
This data center is now exclusively represented by Beijing Risheng Tianxin. There are many institutions that cooperate with this company below.
What is the specific bandwidth quality? Please test it yourself.