PPR water pipe joints thermal fusion using method:
1, the welding device will be fixed to install the heating end of the welding device will be placed on the rack, according to the required pipe specifications to install the corresponding heating mold, tightened with hexagonal sockets, generally in the former small.
2, power on and off (note that the power supply must be equipped with grounding protection wire). Green indicator light, the red indicator light off, indicating that the solder is in the automatic control state, you can start the operation. In the automatic temperature control state, the red light and green light alternately self-lighting, indicating that the welding device is in a controlled state, does not affect the work.
3, welding pipe cut off the pipe cutting machine vertical pipe, pipe and fittings at the same time rotating welding fixture, to achieve the heating time of the pipe and fittings immediately from the die head at the same time, quickly and without continuous rotation uniformly inserted into the required depth, in order to *** with the formation of a uniform flange.
Extended information:
Do not tamper with the plug during operation, and the hand plug must be inserted into a socket with a grounding wire when in use. In the process of use, the hand and flammable material can not touch the electric fusion heat block part to avoid accidents. Non-professionals should not open the product to prevent electric shock and damage to the safety performance of the instrument.
If the red indicator does not jump for a long time, it means that the instrument has a fault, it should stop working immediately and cut off the power supply. If there is a malfunction, it should be sent to the local distribution office or manufacturer for maintenance, and the user shall not disassemble it at will. If the operating environment temperature is lower than 5℃, the heating time will be extended by 50%.
The temperature of the fusion splicer has been adjusted at the factory, non-professionals shall not be adjusted arbitrarily, so as not to affect the normal use of the fusion splicer and the life of the fusion splicer.
If it is outdoors, or in winter, should increase the heating time, and holding time. Generally the temperature of the thermal fusion machine is set, do not change. If you want to change it, you should adjust it gradually according to the actual situation of the site. After using it a few times, it is good to have experience.
If you don't know how to do it, don't move it yourself, you should find a professional maintenance personnel or go to the maintenance center, let the maintenance master to deal with it, so as not to cause unnecessary trouble!