Shenzhen Hangchuang Medical Equipment Co.

Automatic Ion Analyzer

Automatic Ion Analyzer HC-800 Analyzer (Fluorine\Nitrate Nitrogen\PH)

Main Performance Parameters: Measurement Methods Electrode Measurement Online Measurement Mode Start the Instrument at Any Interval Online Measurement Mode Measurement Range (mg/L) 0.3≤F≤190 , 1≤NO3-N≤850 ,2≤ PH≤12 Resolution 0.1mv Potentiometric Error ≤± 1%FS Response Speed 60 seconds to reach 97% Measurement Period ≤ 3 min Repeatability Error F≤± 5% , 1≤NO3-N≤850 , 2≤ PH≤12 PH≤12 Resolution 0.1mv Potential error ≤± 1%FS Response speed 97% in 60 seconds Measurement cycle ≤ 3 min Repeatability error F≤± 5% NO3≤± 5% PH≤± 5% Printer Thermal printer Digital interface USB interface Control and display Large screen Chinese LCD with backlight, each line can display 15 Chinese characters or 30 English characters Power supply and temperature & humidity AC220V ±22V, 50Hz, 8 ~ 40 ℃, ≤ 90% grounded, beyond the range of the need to start the air conditioning Overall dimensions, weight 38.5 × 23.5 × 34.5 cm, net weight of the host

8 kg net dimensions, excluding packaging Fully Automatic Ion Analyzer HC-800 Fully Automatic Ion Analyzer (PH / Chlorine / Water Hardness / Sodium / Potassium)

Main Performance Parameters: Measurement Method Electrode Measurement Online Measurement Mode Any set interval to start the instrument online measurement mode Measurement Range (mg/L) 0.5 ≤ Na ≤ 4000 1 ≤ CL ≤ 1500 0.5 ≤ WH ≤ 1500 (according to CaCO3)

0.5 ≤ K ≤ 390

2 ≤ PH ≤ 12 Resolution 0.1mv Potential Display error ≤± 1%FS Response speed 97% in 60 seconds Measuring period ≤ 3 min Repeatability error Na≤± 5% CL≤± 5% WH≤± 5%

K≤± 5% PH≤± 5% Printer Thermal printer Digital interface USB interface Controls and displays Extra-large screen with backlit Chinese LCD display, each line can display 15 Chinese characters or 30 English characters Power supply and humidity Temperature and humidity AC220V ±22V, 50Hz, 8 ~ 40 ℃, ≤ 90% grounded, beyond the range of the need to start the air conditioning Overall dimensions, weight 38.5 × 23.5 × 34.5 cm, the host of the net weight of 8 kg Net dimensions, excluding packaging Fully Automatic Ion Analyzer HC-800 Automatic Ion Analyzer (PH / Chlorine / Sodium / Potassium / Calcium)

To be performance parameters: Measurement Method Electrode Measurement Online Measurement Mode Any set interval to start the instrument online measurement mode Measurement Range (mg/L) 0.5 ≤ K ≤ 390 0.5 ≤ Na ≤ 4000 1 ≤ CL ≤ 1500 20 ≤ Ca ≤ 120

2 ≤ PH ≤ 12 Resolution 0.1mv Potential Oscillator Error ≤ ± 1%FS Response Speed 60 seconds to 97% Measurement Period ≤ 3 min Repetition Error Cycle time ≤ 3 min Repeatability error K ≤ ± 5% Na ≤ ± 5% CL ≤ ± 5% Ca ≤ ± 5% PH ≤ ± 5% Printer Thermal printer Digital interface USB interface Controls and displays Extra-large screen with backlit Chinese LCD, each line can display 15 Chinese characters or 30 English characters Power supply and temperature and humidity AC220V ±22V, 50Hz, 8 ~ 40 ℃, ≤ 90% grounding, beyond the range of the need to start air conditioning Outside the range of the need to start the air conditioning dimensions, weight 36 × 26.5 × 40 cm, the host net weight of 8 kg net size, excluding packaging HC9883 Electrolyte Analyzer

HC-9883 Electrolyte Analyzer uses the international advanced ion-selective electrode. The instrument is controlled by advanced microprocessor system, realizing fully automatic detection. It can detect potassium, sodium and chlorine items at the same time.

HC9884 Electrolyte Analyzer

HC-9884 Electrolyte Analyzer adopts internationally advanced ion-selective electrodes, and its sensitivity, stability, and anti-interference ability of potassium, sodium, and chlorine electrolyte detection of the whole machine have reached the advanced level of the similar foreign models. The Chinese operation information management system of the instrument meets the needs of medical units. The original use of pressure sensor measurement technology in carbon dioxide detection not only ensures the accuracy of the experiment, but also greatly simplifies the complex steps of the reference method. The set of instruments is controlled by advanced microprocessor system, realizing fully automatic detection. It can simultaneously detect potassium, sodium, chlorine, total carbon dioxide, anion gap and other items.

HC9885 Electrolyte Analyzer

HC-9885 Electrolyte Analyzer adopts internationally advanced ion-selective electrode. The sensitivity, stability and anti-interference ability of potassium, sodium, chlorine and calcium electrolyte detection of the whole machine have reached the advanced level of similar foreign models. The Chinese operation information management system of the instrument meets the needs of medical units. The instrument adopts advanced microprocessor system control, realizing fully automatic detection. It can simultaneously detect potassium, sodium, chlorine, PH, total calcium, standard ionized calcium and other items.

HC9886 Electrolyte Analyzer

HC-9886 Electrolyte Analyzer adopts the internationally advanced ion-selective electrode, which ensures the accuracy of the experiment and greatly simplifies the complicated steps of the reference method. The instrument is controlled by advanced microprocessor system, realizing fully automatic detection. It can simultaneously detect potassium, sodium, chlorine, total calcium, standard ionized calcium, PH, total carbon dioxide, anion gap and other items.

General Purpose Autosampler

Main Features:

1. The autosampling tray is equipped with 30 sample points, 1 emergency point (M point), and 1 automatic flushing waste liquid point (W point). High degree of automation, automatic sampling, cleaning, calibration, calibration, display of results and printing and other work.

2. It can be equipped with an autosampling tray to constitute a fully automatic electrolyte analysis system. It can improve the working efficiency when there are many samples per day and batch processing is required