Pathogenic microorganisms laboratory biosafety management measures in Zhejiang Province, which laboratories need to be filed according to law

All localities should strictly implement the "Zhejiang Provincial Department of Agriculture on the issuance of the notice" (Zhejiang Agricultural Government issued 〔2013〕 No. 7), engaged in animal pathogenic microbial strains (viruses), samples related to research, teaching, testing, diagnostic activities of the first and second level of laboratories (including third-party laboratories, hereinafter the same) for the record management. Municipal departments of agriculture and rural areas specifically responsible for the jurisdiction of the laboratory for the record registration management, county-level agricultural and rural departments to guide and supervise the jurisdiction of the laboratory to do a good job for the record. For the new construction, alteration and expansion of biosafety level 1, level 2 laboratories, should be built in the laboratory within 30 days after the completion of the municipal agricultural and rural departments to the location of the record. Laboratory responsible person, biosafety responsible person, site and other major filing items change, should be changed within 30 days from the date of change to the original filing authority to re-file. First, P1 level laboratory general specifications

1, the laboratory has the same level of general microbiology laboratory equipment.

2. If non-recombinant experiments are conducted simultaneously in this level of laboratory, the experimental area should be clearly delineated and carefully operated.

3. When conducting experiments, it is advisable to close the doors and windows of the laboratory.

4. Sterilization of the laboratory bench is required at the end of each day's experiment, and if contamination occurs during the experiment, it should be sterilized immediately. Second, P2 laboratory general specifications

1, the need to set up biosafety devices (* or second level), and to do regular checks.

2. When equipment such as grinders, freeze dryers, ultrasonic cell breakers, and centrifuges, which are prone to generating aerosols, are used for the processing of recombinant bodies, they must be placed in a safe operating device. However, if the machine is already equipped with a device to prevent the leakage of aerosols, this is not required.

3. The laboratory should have an autoclave for sterilizing contaminants and wastes, * placed in the same room. If there are difficulties, it can be placed in neighboring places.

4, the laboratory should be equipped with UV lamps and double doors, if not double doors, the door must be closed.

5, the laboratory should be equipped with foot or elbow operation or automatic hand washing device. Legal basis: "Emergency Regulations on Major Animal Epidemics" Article 21 The collection of highly pathogenic pathogenic microorganisms samples of the staff in the collection process should prevent the spread of pathogenic microorganisms and infections, and the source of the sample, the collection process and method of making detailed records. The competent departments of animal husbandry and veterinary medicine in each region shall strengthen the safety supervision of the collection and use of diseased materials. The laboratories and their establishment should strengthen the relevant experimental activities of the disposal of waste supervision, to ensure complete sterilization, flow traceability.