What kind of oil to add to the pneumatic triplex

Use JIS K2213 oil (ISO Vg32 or equivalent) for the pneumatic triplex oiler. Do not add more than one-eighth of a cup full of oil. The number 0 is the minimum amount of oil and 9 is the maximum amount of oil. From 9-0 position can not be rotated, must be turned clockwise.

If the pressure reducing valve of the air filter is designed as a whole, it is called a dichotomy.? Air source treatment triplex includes air pressure reducing valve, filter, oil mist three major components, pressure reducing valve can be stabilized on the air source, so that the air source is in a constant state, which can reduce due to sudden changes in air pressure on the source of air pressure on the valves or actuators and other hardware damage.

Extended information:

Pressure adjustments, before turning the knob, please pull up and then rotate it, and press the rotary knob for positioning. Turn the knob clockwise to adjust the outlet pressure up, and counterclockwise to turn down the outlet pressure. When adjusting the pressure, it should be adjusted gradually and evenly to the desired pressure value, and should not be adjusted in one step.

Feeder JIS K2213 oil (ISOVg32 or equivalent). Please do not add oil more than eight parts full of the cup. The number O is the minimum amount of oil, 9 is the maximum amount of oil. From 9-0 position can not be rotated, must be rotated counterclockwise.

With air and inert gas as the working medium, air is supplied in sufficient quantity and at no cost. More importantly, air and inert gas do not cause pollution to the surrounding environment, is a clean medium. Pneumatic technology can do long-distance air supply, reduce local mechanical equipment, save plant space.

Baidu Encyclopedia - Pneumatic Triad