Classification of pharmaceutical warehouses and classification of facilities and equipment

Categorization of pharmaceutical warehouses and classification of facilities and equipment:

Categorization of pharmaceutical warehouses:

(a) Effective isolation of equipment between pharmaceuticals and the ground, such as floor mats, shelves. The height between the floor mats, shelves, etc. and the ground is not less than 10 cm. medicines shall not directly touch the ground at any time.

(ii) equipment to avoid light, ventilation, moisture, insects, rodents, etc.; such as curtains, blackout film, air conditioners, ventilation fans, floor mats, shelves, curtains, curtains, electronic cats, rodent panels, fly lamps, mousetrap cages, sticky rodent glue.

(3) Equipment that effectively monitors and regulates temperature and humidity; such as air-conditioning systems, humidifiers, dehumidifiers, etc.

(d) there should be automatic monitoring and recording of the temperature and humidity of the warehouse equipment, such as automatic temperature and humidity monitoring system: probe, display, computer, etc., automatic monitoring and recording of the temperature and humidity of the warehouse, and can be in the temperature and humidity exceeds the standard automatic alarm.

(E) lighting equipment in line with the requirements of storage operations.

(F) there should be used for zero picking, consolidated shipping operations and review of operational equipment, such as zero boxes, crates, transport boxes, sealing glue, labels, bar code collectors and other equipment.

(VII) there should be packaging materials storage, acceptance, delivery, return of special places, unqualified drugs special storage places, the above places should be mats, shelves and so on.

(h) should have fire safety facilities and equipment, such as fire extinguishers, fire poke, fire hose.

(IX) should be used for goods in the warehouse handling equipment, such as carts, carriers.

(J) according to the scope of business, there should be a backup refrigerator or small cold storage.

(k) should have the type of warehouse and classification of drugs stored in the signage, classification boards, isolation zones.

Categorization of facilities and equipment:

(a) its scale of operation and variety of cold storage, storage of vaccines should be equipped with more than two independent cold storage.

(b) for cold storage temperature automatic monitoring, display, recording, regulation, alarm equipment.

(c) cold storage refrigeration equipment backup generator sets or double circuit power supply system.

(d) of special low-temperature requirements of drugs, should be equipped with facilities and equipment to meet its storage requirements.

(E) refrigerated trucks and car refrigerator or insulated box and other equipment. Transportation of drugs should be used closed cargo transportation.