1, the vibration plate does not work the possible reasons
1, the power supply voltage is insufficient
2, the vibration plate and the controller between the broken wires
3, the controller fuse blown
4, the coil is burned out
5, the coil and the skeleton gap is too small or too large
6, there are parts stuck between the coil and the skeleton
4, the table is not level
5, there is debris in the disk
6, the coil air gap should be as small as possible
7, the machine tempo is too fast resulting in parts from the vibration plate slipped.
8, power grid fluctuations
9, the controller needs to be readjusted to adapt to power grid fluctuations.
10, parts problems: super poor, bending, oil, etc.
11, disk and base fastening screws are not tight or not in the right position.
12, too many parts
13, the chassis is not properly adjusted
14, the material changes, should be re-trimmed disk and re-adjustment of the chassis
15, in the use of air blowing occasions may produce some problems, there may be: unstable air pressure, air pollution, water or oil, these contaminants will be stagnant in the surface of the vibration disk, resulting in feeding slowed down or even does not go. The air source must be clean and dry, with separate regulators and filters. Do not use rigid tubing as it will degrade feeding performance. A flexible hose should be used.