Pharmaceutical plant with purified water equipment process flow how many?
1, raw water → raw water pressurization pump → multi-media filter → activated carbon filter → water softener → precision filter → a reverse osmosis equipment → intermediate tank → intermediate pump → ion exchanger → purified water tank → pure water pump → ultraviolet sterilizer → microporous filters → point of water
2, raw water → raw water pressurization pump → multi-media filter → activated carbon filter → water softener → precision filter Filter → water softener → precision filter → first-stage reverse osmosis → PH adjustment → intermediate tank → second-stage reverse osmosis (reverse osmosis membrane surface positive charge) → purified water tank → pure water pump → ultraviolet sterilizer → microporous filters → water points p>
3. Raw water → raw water pressurized pump → multi-media filter → activated carbon filter → water softener → precision filter → first-stage reverse osmosis → intermediate tank → intermediate pump → EDI system → water tank p>
4. Intermediate water pump → EDI system → purified water tank → pure water pump → ultraviolet sterilizer → microporous filter → water point
The national water requirements for the medical and pharmaceutical industries are very strict, purified water is the main water for medical and pharmaceutical industries, blue membrane water treatment research and development of water purification equipment needs to comply with the "Chinese Pharmacopoeia", purified water equipment needs to meet the national GMP certification / U.S. FDA The water purification equipment needs to meet the national GMP certification / U.S. FDA certification requirements.
For more information, please click: web link
.