This laboratory can be based on GB4208, IEC/EN 60529 "enclosure protection level (IP code)" standard for IP protection level testing and identification.
Frequently tested IP ratings are: IP44, IP54, IP55, IP65, IP67, IP66, IP68 and so on.
The laboratory is equipped with rain shower laboratory, stainless steel material vertical rain, pendulum pipe
rain, spray, splash, flooding and other waterproof test equipment, according to the national or international standards, industry standards, customer requirements, and other conditions for testing, testing.
At the same time, the laboratory also has sand and dust test chamber, can be sand and dust test.
Laboratory Advantages:
High authority: the testing center meets the requirements of ISO/IEC17025: 2005 "General Requirements for the Competence of Testing and Calibration Laboratories" (CNAS) "Guidelines for Recognition of the Competence of Testing and Calibration Laboratories"), and has the qualification of metrological accreditation of the Certification and Accreditation Administration of the People's Republic of China (CMA), which allows the community to issue data and results with a The data and results can be issued to the society with the function of proving.
Report cycle: 5-7 working days to get the test report;
More affordable,
Good service: the laboratory in line with the purpose of the customer is God, to provide quality service for the majority of customers;
1, the shell protection test introduction
Shell protection test, usually also known as the IP level test, is mainly used to evaluate Various types of electrical products shell and seals in the dust, moisture, water or diving and other harsh environmental conditions, the reliability of its shell protection to verify that the product and component performance will be damaged, but also to prevent human contact with hazardous components to provide the appropriate protection requirements.
IP is an abbreviation for INTERNATIonAL
PROTECTION, which means internationally recognized level of protection. IP protection level is generally composed of two numbers or additional letters: the first number indicates the level of protection against entry of solids, and the second number indicates the level of protection against water entry. The larger the number, the higher the level of protection.
2. Inspection Scope
Product Scope
Household Appliances
Automotive Components
Electric Tools
Lighting Appliances
Information Technology Equipment
Audio and Video Equipment
Medical Devices
Power Supply Equipment
Wireless Products
Electrical Accessories
Outdoor Equipment
Marine/Fishing Equipment
Test Items
IP Rating Domestic and Foreign Test Reports
IPX1~IPX2 Drip Test
IPX3~IPX4 Drenching Test
IPX5~IPX6 Flushing Test
IPX7 water immersion test
IPX8 (customer conditions) submersion test
IP1X~IP4X anti-solid/electrocution protection
IP5X dust test
IP6X dust tightness test
Other dust and waterproof test
National product testing: Shanghai ___ Tianjin ___ Changchun ___ Chongqing ___ Beijing ___ Chengdu _ Shanxi_Shaanxi_Shanghai_Zhejiang_Jiangsu_Wuhan_Guangdong_Shandong_Fujian_Zhengzhou_Changsha
Conducted to accept the test project: far-infrared inspection _LED lamps and lanterns testing _Lamps and lanterns optoelectronic performance testing _Lighting design documents IES for _Electronic and electrical safety testing
_Reliability test _Electromagnetic compatibility test _IP protection level test _IK anti-collision level test _Eco-textile testing _Microbial testing _Hazardous substances testing and analysis _Materials negative ion generation testing - magnetic field strength testing
Conduct CE, CB, FCC, VCCI, PSE, UL, ETL, MET, E-Mark, FDA, C-Tick,
TUV, NEMKO, GCF, CDG, SASO, PTCRB, CEC, MEPS, VDE and other international certification testing,
IP (INGRESS PROTECTION) protection level system is drafted by IEC (INTERNATIONAL ELECTROTECHNICAL COMMISSION). The electrical appliances are graded according to their dust and moisture resistance. The external objects referred to here include tools, human fingers, etc. are not allowed to contact the charged parts of the electrical appliances to avoid electric shock. IP protection level is composed of two numbers, the first number indicates that the lamps and lanterns are free from dust, preventing the intrusion of foreign objects, the second number indicates that the lamps and lanterns are moisture-proof, waterproof intrusion of the degree of confinement, the bigger the number indicates that the higher the level of protection.
Additional letters: Protection from dangerous parts
A Back of hand
B Fingers
C Tools
D Metallic wires
Supplementary letters: Specialized additional information
H High-voltage equipment
M Running of specimen during waterproofing test
S Stationary specimen during waterproofing test
W Climatic conditions
Waterproofing test
Waterproofing test
Waterproofing test
Waterproofing test
W Climatic conditions
-Waterproof test
1. Scope
The waterproof test includes the second characteristic digit from 1 to 8, i.e., the protection level code from IPX1 to IPX8.
Testing method of IP67
Firstly, it is necessary to understand the product's specific ability to withstand the product's waterproofing and dustproofing severity level (the interpretation of the waterproofing and dustproofing severity level is shown below). waterproof and dustproof severe grade interpretation)
Second Looking for authoritative testing organizations (professional authoritative laboratory, the International Electrotechnical Commission IEC authorized laboratory issued ip68 waterproof and dustproof grade quality inspection report, can make the product to get international recognition, absolute authority | affordable)
Third The factory is worried about the product test, but you can take the following approach: in accordance with the following test severity rating method Simple simulation of the test product testing once (simulation is completed after the need to hit the product to see if there is water inside)