Hospital sterilization of surgical instruments with what biocides
Surgical instruments, generally first with running water to brush the blood, and then, carefully check the instruments, medical suture needles, medical surgical blades, are directly thrown away without cleaning, instrument inspection if found unqualified instruments, timely elimination, will be qualified instruments, sent to the ultrasonic cleaner, shock cleaning, and then, air-drying, the instrument room will be the sharp things, such as razor blades, suture needles, mounted on the needle box, and then, and other instruments, surgical towels, wrapped in a large blue cloth surgical instrument bag. Accessories, surgical towels, wrapped in a large blue cloth surgical instrument bag, and then tie the string, put on the autoclave sterilization instructions stickers, sent to the autoclave sterilization pot disinfection, each sterilization pot, put the sterilization instructions card, 5 stays the point of the thermometer, inserted in the upper left, right middle, left bottom, right bottom disinfection for 30 minutes, the parcel should not be larger than 55 by 33 by 22 CM can also be sterilized by boiling for 2 hours, or can be used with 0.1% Neosporin soak for 30 minutes, and the parcel can also be sterilized with 0.5% Neosporin. New Cleaner Soak for 30 minutes, or 0.1 Chlorhexidine for 30 minutes, or boil for 1 hour, then use 0.2 glutaraldehyde, soak for 10 hours, thoroughly disinfected.