1, weekly inspection, replacement of the hot air generator cabinet at the bottom of the circulating return air filter cotton once, not allowed to draw away the hot air generator cabinet at the bottom of the circulating return air filter cotton, for the uncovered circulating back to the wind (for the high-end diesel paint booths)
2, the maintenance of all parts and components must be used by the manufacturer of the parts and components provided by the manufacturer
3, when checking or cleaning all ventilation ducts, carefully remove dirt and paint sludge under the condition of ensuring safety, more than one overhaul is required in a year;
4, checking the correct isolation and fastening of each electrical terminal, whether the grounding resistance of each high-power equipment and electrical cabinet is in accordance with the national standard, whether the insulation resistance is in accordance with the national standard, more than one overhaul is required in a year;
5, Regularly check the top of the static pressure chamber and hot air generator cabinet within the high-temperature-resistant power lines (every 8-12 months), such as found that the aging of the wire must be replaced with high-temperature-resistant power lines, in order to avoid the occurrence of a power short-circuit caused by a fire;
6, check the sealing of sealing parts of the sealing situation (room body, thermal generator cabinet, air intake and exhaust system, etc.), a year to be more than one overhaul;
7, all the routine Maintenance and regular maintenance, must cut off the main power switch of the baking room;
8, regular 3-5 months to check the fan bearing seat, fan base and other connecting parts of the bolt tightness and lubrication of the rotating parts;
9, regularly according to the accumulator, maintenance records to check the replacement of the top cotton, air intake filter cotton, ground net filter cotton, exhaust filter cotton and activated carbon filter cotton layer;
10, regularly clean the lights, wall panels on the dirt and paint channel;
11, regularly on the compressed air system filtration part of the cleaning, sewage, maintenance;
12, regularly on the diesel fuel filter cartridge replacement (every 8-12 months), on the high pressure oil pump filter cleaned every 6 months, on the high-pressure nozzle filter cleaned once a year;
p>13, regularly check whether the oil tank leakage, maintenance and cleaning every season;
14, regularly check whether the instrumentation is working properly, whether the safety devices are working properly, a year need to overhaul more than once.
15-electrically heated paint booth paint lamps are not used for a long time, paint on the surface of the baking lamp must be baked until there is no smoke can be used normally
16-strictly forbidden to block the observation window, open the baking lamp before you must look at whether there is no newspaper and other flammable materials in the baking lamp
17-baking process staff can not be away from a long time